For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
REF | DESCRIPTION | DOWNLOADS | PRICE | ORDER ITEM |
---|---|---|---|---|
GRD-4GM Series Data Logger | ||||
GRD3621-XF-4GM |
GRD3621-XF-4GM 4G/GPRS data logger and SMS alarm unit. USB port available for local programming and configuration. 4 configurable digital I/Os, suitable for digital state, alarm outputs or pulse inputs at up to 45Hz. 2 configurable analogue inputs, suitable for 0-1V, 0-10V or 4-20mA inputs, 1 suitable for PT100 inputs. Power Supply: 10-30vDC. The GRD can send SMS alarm messages directly from the unit for any alarm conditions. Script programming allows for simple operations and math functions on input channels. GRD unit has an internal back-up memory for up to 100,000 readings in the event of connection issues with mobile network or remote server. | £832.92 |
or call us for a quote
|
|
GRD3625-XF-4GM![]() |
GRD3625-XF-4GM 4G/GPRS data logger and SMS alarm unit. USB port available for local programming and configuration. One RS232 and one RS485 serial ports available for ModBus Master (reads up to 100 registers) and ITAS Satellite modem communications. 6 configurable digital I/Os, suitable for digital state and alarm outputs, plus 4 channels suitable for pulse inputs at up to 45Hz. 4 configurable analogue inputs, suitable for 0-1V, 0-10V or 4-20mA inputs. Power Supply: 10-30vDC. The GRD can send SMS alarm messages directly from the unit for any alarm conditions and also activate digital outputs from received SMS instructions. Script programming allows for simple operations and maths functions on input channels. GRD unit has an internal back-up memory for up to 100,000 readings in the event of connection issues with mobile network or remote server and to allow for data batching for satellite transmission. | £845.04 |
or call us for a quote
|
|
GRD3534-XF-4GM![]() |
GPRS RTU, 1 USB Port, 8 analogue inputs, 0-1v 0-10v/4-20mA, 16 digital channels, configurable as digital state or pulse inputs (Max 8 at 1kHz), 8 channels selectable via jumpers as outputs. Dual RS485/232 ports. Embedded Modbus Master on RS232/RS485. Up to 100 registers (4x, 3x, 0x and 1x Modbus registers) -Historical records: 100,000, Current, Average, Maximum, Minimum. | £960.73 |
or call us for a quote
|
|
GRD1620-XF-4GM![]() |
GRD1620-XF-4GM Remote Data Logger. 4G, 3G, 2G and SMS Serial Server (LTE Cat 1 Global). Ideal Remote Data Logger/SMS Alarm Unit. One RS232 and one RS485 serial ports available for ModBus Master (reads up to 100 registers) and ITAS Satellite modem communication option. USB port available for local programming and configuration. The GRD can send SMS alarm messages directly from the unit for any alarm conditions. Script programming allows for simple operations and maths functions on input channels. GRD unit has an internal back-up memory for up to 100,000 readings in the event of connection issues with mobile network or remote server and to allow for data batching for satellite transmission. Power Supply: 10-30vDC. | ![]() Size: (6.77 MB) |
£683.09 |
or call us for a quote
|
SP-LITE-EX SENS![]() |
SP-LITE Pyranometer is suitable for solar irradiance measurements in spectral ranges of 400 to 1100nm up to a maximum of 2,000 W/m² with response time less than 1 seconds and typical sensitivity of 60 to 100µV/W/m² that varies less than 0.15%/°C from -30 to +70°C. The pyranometer uses a Double 2mm glass domes to protect the thermopile from external influences. SP-LITEs are fitted with 5m of cable for direct connection to a data logger. | ![]() Size: (524.7 KB) |
£405.00 |
or call us for a quote
|
CMP3![]() |
CMP 3 Pyranometer, ISO Second Class, is suitable for solar irradiance measurements in spectral ranges of 310 to 2800nm up to a maximum of 2,000 W/m² with response time <18 seconds and typical sensitivity 10µV/W/m² that varies less than 5 % from -10 to +40°C. The pyranometer uses a 4mm dome to protect the thermopile from external influences. CMP3s are fitted with 10m of cable for connection to amplifier, data loggers and other instrumentation. | ![]() Size: (487.19 KB) |
£561.00 |
or call us for a quote
|
OMNI-C1-10V |
Omni C Series Current Transducer. Selectable current ranges: 0-10, 0-20 or 0-50A with a 0-10V output, accuracy 1%FS. Suitable for single phase circuits with a frequency 40-400Hz. Isolation voltage 2000V. Split core transducer with a 20 x 22mm conducer hole. Certification: CE, UL and RoHS. | ![]() Size: (136.02 KB) |
£93.53 |
or call us for a quote
|
OMNI-C2-10V |
Omni C Series Current Transducer. Selectable current ranges: 0-100, 0-150 or 0-200A with a 0-10V output, accuracy 1%FS. Suitable for single phase circuits with a frequency 40-400Hz. Isolation voltage 2000V. Split core transducer with a 20 x 22mm conducer hole. Certification: CE, UL and RoHS. | £79.00 |
or call us for a quote
|
|
CMP11![]() |
CMP 11 Pyranometer, ISO Secondary Standard, is suitable for solar irradiance measurements in spectral ranges of 310 to 2800 nm up to a maximum of 4,000 W/m with response time less than 5 seconds and typical sensitivity of 7 to 14µV/W/m that varies less than 1 % from -10 to +40°C. The pyranometer uses a Double 2 mm glass domes to protect the thermopile from external influences. CMP11s are fitted with 10m of cable for connection to a TxRail or DigiRail-2A module to GRD Solar Efficiency Monitor. | £2,466.00 |
or call us for a quote
|
|
E13050 |
PT100 Class B 3-wire temperature probe to monitor solar panels temperatures. Probes are fitted with 1m flying lead and a 6mm surface mount leaf for mounted to solar panel surfaces. This sensor is ideal monitoring surface temperatures for temperature co-efficiency adjustments in solar panel power generation. | ![]() Size: (178.63 KB) |
£53.95 |
or call us for a quote
|
HBS/1/1832/CLASSA/5M |
PT1000 Temperature Probe to monitor solar panels temperatures. Probes are fitted with 5m PVC flying lead and an aluminium leaf (24mm x 10mm) for mounted to solar panel surfaces. Temperature readings can be used for temperature coefficiency adjustments in solar panel power generation. | £77.44 |
or call us for a quote
|
|
HBS/1/2896 |
PT1000 Air Temperature Probe with Aluminium housing. Temperature range -40 to +80 C. | £113.49 |
or call us for a quote
|
|
HygroClip 2 Advanced Probes | ||||
HC2A-S![]() |
Standard HygroClip 2 Temperature and Relative Humidity Probe. Temperature Range: -50 to +100°C and Humidity 0-100%. Accuracy: ±0.1°C and ±0.8%RH. Outputs: 0-1V. Comes with a black Polycarbonate housing and a Polyethylene (40µm) filter. Sensor Element: Hygromer HT-1. Ideal for general purpose portable measurements in open spaces, warehouses, museums or factory floors. Max wind speed 20m/s. | ![]() Size: (564.17 KB) |
£281.00 |
or call us for a quote
|
Stevenson Screen | ||||
SCREEN-MODEL-306![]() |
Stevenson screen to protect the air temperature probe from the affects of rain and wind on the temperature reading. The white UV stabilized thermoplastic discs offer a high reflectivity, low thermal conductivity and rugged weather resistance. Stainless Steel mounting bracket suitable for pipes up to 27mm, or direct connection to a flat surface. Dimensions: 85mm diameter and 80mm high. | £75.48 |
or call us for a quote
|
|
Enclosure Mounted Amplifier | ||||
5331A3B-ENCL |
5331A3B programmable transmitter with a 7.2-35vDC power supply. Single channel unit for PT100, thermocouple, Resistance or bi-polar mV input, producing a 2-wire 4-20mA output. 1.5kvAC galvanic isolation. Programmed to suit the connected sensor. Transmitter fitted in weatherproof enclosure with 2 cable glands. | ![]() Size: (245.66 KB) |
£254.19 |
or call us for a quote
|
Yacht Anemometers | ||||
95.0146![]() |
Meteo anemometer self-powered rotating cup anemometer for wind speed. Air velocity range 2.5 - 210Km/h , accuracy ±0.3m/s, ±5% of reading, output 0-2.1vDC (1V = 100Km/h). This product does not include an indicator. | ![]() Size: (148.66 KB) |
£419.51 |
or call us for a quote
|
DER-10A-60MV |
DER Type, Standard DIN DC Current Shunt. Range 10A Current Range with a proportional 0-60mV Output. | ![]() Size: (248.83 KB) |
£13.10 |
or call us for a quote
|
DER-20A-60MV |
DER Type, Standard DIN DC Current Shunt. Range 20A Current Range with a proportional 0-60mV Output. | £13.10 |
or call us for a quote
|
|
TM2UA76![]() |
TM2U AC voltage transducer, single phase input range 0-250vAC, self supplied, output 0-5vDC. Accuracy 0.5% (20-120% of range), operating temperature -10 to 55°C. | ![]() Size: (328.98 KB) |
£74.28 |
or call us for a quote
|
TM2UAA6![]() |
TM2U AC voltage transducer, single phase input range 0-440vAC, self supplied, output 0-5vDC. Accuracy 0.5% (20-120% of range), operating temperature -10 to 55°C. | £74.28 |
or call us for a quote
|
|
CS-SP10L![]() |
CS Series Current Transducer. Jumper selectable Current Ranges: 0-10, 0-20 or 0-50A with a self-powered 0-10V Output, Accuracy ±1%FS, Response Time: 0.5 Seconds. Suitable for single phase circuits with a frequency 40-100Hz. Isolation voltage 600vAC RMS. Solid Core transducer with a 22.6mm conductor hole. UL94V-0 flamablility rated ABS enclosure 63 x 100 x 32mm, Certification: CE, UL and RoHS. | £106.41 |
or call us for a quote
|
|
FCS2151-SP-10V![]() |
Omni C Series Current Transducer. Selectable current ranges: 0-100, 0-150 or 0-200A with a 0-10V output, accuracy 1%FS. Suitable for single phase circuits with a frequency 40-400Hz. Isolation voltage 2000V. Split core transducer with a 20 x 22mm conducer hole. Certification: CE, UL and RoHS. | £117.25 |
or call us for a quote
|
|
PRO1D-MID![]() |
MID Certified PRO1D Energy Meter. 18mm wide DIN Rail mounting, LCD display, suitable for single phase networks measuring voltage 230vAC 50Hz, current range 0-45 amps, comes with a pulse output. MID approved suitable for billing purposes accuracy class B (EN50470.03). Suitable for measuring the kWh generated by the solar panels in single phase systems at 400V and a maximum current of 45 Amps. Meters are self powered and connect directly to the generated power. Meters generate pulse output for direct connection to GRD Solar Efficiency Monitor. | ![]() Size: (289.11 KB) |
£32.80 |
or call us for a quote
|
RI-D19-80C![]() |
RI-D19 Energy Meter. Suitable for measuring the kWh generated by the solar panels in single phase systems at 230V and a maximum current of 80 Amps. Meters are self powered and connect directly to the generated power. Meters provide an RS485 Modbus output for direct connection to GRD Solar Efficiency Monitor. | ![]() Size: (390.53 KB) |
£31.50 |
or call us for a quote
|
CE4DMID001![]() |
MID Certified Conto-D4-Pt Energy Meter. Suitable for measuring the kWh generated by the solar panels in three phase systems in either 230V or 400V ranges. Meters use 5A CT Clamps for current measurement of each phase and generate pulse and RS485 Modbus outputs. Power Supply 230V. Suitable for submetering applications or solar panel efficiency monitoring. | ![]() Size: (535.08 KB) |
£183.47 |
or call us for a quote
|
Curent Clamps | ||||
DBP23100/5A![]() |
DBP23 Series split core current transformer. Primary current range 100A AC, secondary current range 5A. Dimensions 109 x 89 x 40mm with a 20 x 30mm window. | £19.23 |
or call us for a quote
|
|
TAS227100/5A![]() |
TAS227 Series fixed core current transformer. Primary current range 100A AC, secondary current range 5A. Dimensions 185 x 84 x 45mm with three 27mm diameter apertures. | £19.22 |
or call us for a quote
|
|
DigiRail Modules | ||||
8811100000![]() |
DigiRail-2A, Dual Universal Analogue Input. The unit provides a dual channel input for Thermocouples, PT100, mV, V and mA inputs with a RS485 ModBus output. The units provide a internal CJC for thermocouples and both input channels and the RS485 port are fully isolated up to 1,000V. Units are DIN Rail mountable with a working temperature of 0 to 70°C and supplied with the DigiConfig software to allow configuration. | ![]() Size: (169.15 KB) |
£82.03 |
or call us for a quote
|
8811400100![]() |
DigiRail-4C Module, suitable for converting 4 Counter/Digital Input to RS485 Modbus. The unit provides a four channel input for Digital Inputs, suitable for pulse or digital state inputs, with a RS485 ModBus output. The units four input channels and the RS485 port are fully isolated up to 1,000V. Units are DIN Rail mountable with a working temperature of 0 to 70°C and supplied with the DigiConfig software to allow configuration. Can be used with various GRD, ERD and CMC units to expand the standard channels. | ![]() Size: (169.15 KB) |
£78.65 |
or call us for a quote
|
8811200100 |
DigiRail-2R Module, suitable for dual relay outputs via RS485 Modbus networks. Units are DIN Rail mountable with a working temperature of 0 to 70°C and supplied with the DigiConfig software to allow configuration. Can be used with various GRD, ERD and CMC units to expand the standard channels. | ![]() Size: (129.92 KB) |
£77.30 |
or call us for a quote
|