Battery backup kit comprising of 3.2AH 12v gel cell battery, and inline mains charger. Fitted in ABS wall mount enclosure with mains input terminals and DC O/P terminals. ...
Waterproof 8-pin plug connector with 100m of pre-wired high quality yellow signal cable with 8 wires and a shield covered with black sleeve. Suitable for: For SMP, SGR and SUV5 Smart Radiometers, plus CMP21 (PT100), CMP22 (PT100), CGR3 (PT100), CGR4 (PT100), CHP1, CNR4, UVS, CSD3 ...
One Channel Flatbed Chart Recorder, 200 mm chart roll, 14 measuring voltage ranges from 1 mV to 20 V, (fixed and variable), differential input(s), signals up to 5 Hz, 16 chart speeds from 0.1 mm / min to 20 mm / sec, left or right adjustable zero, shrouded safety input ...
Dual Channel Flatbed Chart Recorder, 200 mm chart roll, 14 measuring voltage ranges from 1 mV to 20 V, (fixed and variable), differential input(s), signals up to 5 Hz, 16 chart speeds from 0.1 mm / min to 20 mm / sec, left or right adjustable zero, shrouded safety input ...
BD300-4. Four Channel data acquisition recorder with AC power cable, 12 fibre pens, 1 packet of Z-floded paper and operating manual. Input range 1mV - 250 vDC/AC, 1mA - 500mA DC/AC, Thermcouples (Types, B, E, J, K, N, R, S, T) & PT100 sensors, sample rate 400Hz, with 250mm chart, ...
BD300 6 Channel chart recorder, input range 1mV - 250 vDC/AC, 1mA - 500mA DC/AC, Thermcouples (Types, B, E, J, K, N, R, S, T) & PT100 sensors, sample rate 400Hz, with 250mm chart, max chart speed 50mm second. Built in datalogger, logs direct to PC or internal 1.44mB floppy ...
BD300 8 Channel chart recorder, input range 1mV - 250 vDC/AC, 1mA - 500mA DC/AC, Thermcouples (Types, B, E, J, K, N, R, S, T) & PT100 sensors, sample rate 400Hz, with 250mm chart, max chart speed 50mm second. Built in datalogger, logs direct to PC or internal 1.44mB floppy ...
20mm Residential Diaphragm Gas Meter. Qmax 6m³/h, Qmin 0.04m³/hr. MID Approved, Fireproof to EN1359. 152.4mm Centres. 1" BS 746 to 3/4" BSP unions included. Fitted with IN-Z61 Pulse transmitter output (100:1 m³) for data to be displayed and logged remotely. ...
GEN II radio transmitter for four external K-Type/T-Type thermocouple probes with display. Range -200 to +200°C, Resolution 0.1°C and Accuracy ±0.3°C. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display. ...
GS-CO2 Carbon Dioxide NDIR Sensor. Measurement Range: 0 to 9999ppm. Accuracy ±0.5%, +30ppm (in range of 0 to 5000ppm), 3 min response time. 6 Byte record length, 297 days logging to internal memory of GL100 unit with a 30 second sampling interval. The GS-CO2 will require a power capacity of ...
The USB-AD16F features 16 Analogue Inputs (selectable ranges of ±1V, ±2V, ±5V, ±10V, with a 250kHz Sampling rate and 16 Bit resolution), 2 Analogue Outputs (10V, with 16 bit resolution), 4 digital inputs and 4 digital outputs (first can be configured as a 19-bit counter) all connected to a PC ...
GEN II radio transmitter for four external K/T Type Thermocouple probe with visual and delayed alarm (High and Low alarm level configured using DARCA software). Temperature Range -200 to +200°C, Resolution 0.1°C and Accuracy ±0.3°C. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display. ...
Backplane for MAL miniature amplifiers: Up to 16 measuring amplifiers, converters, or any other function modules can be integrated in the BP16. If installed close to the signal, it provides for high interference resistance. Ideal for remote signal conditioning of passive sensors. ...
GEN II radio transmitter for four external K/N Type Thermocouple probe. Temperature Range -200 to +1,200°C (K Type) & -200 to +1,300°C (N Type), Resolution 0.5°C and Accuracy ±2°C. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display. ...
GEN II radio transmitter for four external R Type Thermocouple probe. Temperature Range -200 to +2,000°C, Resolution 0.5°C and Accuracy ±2°C. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display. ...
36-inch Development Interface Cable for the MS-IMU3020 Inertial Measurements Sensors. Includes Harwin G125-2041096L0 connector and Hirose HR30-6P-6S termination connector. Cable jacket Silicone Rubber with FEP wire insulation and Stycast 2651, catalyst 9 Encapsulated IMU connector. Total length 36 inches. ...
Battery backup kit comprising of 3.2AH 12v gel cell battery, and inline mains charger. Fitted in ABS wall mount enclosure with mains input terminals and DC O/P terminals. ...
0362625
Waterproof 8-pin plug connector with 100m of pre-wired high quality yellow signal cable with 8 wires and a shield covered with black sleeve. Suitable for: For SMP, SGR and SUV5 Smart Radiometers, plus CMP21 (PT100), CMP22 (PT100), CGR3 (PT100), CGR4 (PT100), CHP1, CNR4, UVS, CSD3 ...
BD11E
One Channel Flatbed Chart Recorder, 200 mm chart roll, 14 measuring voltage ranges from 1 mV to 20 V, (fixed and variable), differential input(s), signals up to 5 Hz, 16 chart speeds from 0.1 mm / min to 20 mm / sec, left or right adjustable zero, shrouded safety input terminals. Operating temperature range - 10C to + 40C. With electrical penlift ...
BD12E
Dual Channel Flatbed Chart Recorder, 200 mm chart roll, 14 measuring voltage ranges from 1 mV to 20 V, (fixed and variable), differential input(s), signals up to 5 Hz, 16 chart speeds from 0.1 mm / min to 20 mm / sec, left or right adjustable zero, shrouded safety input terminals. Operating temperature range - 10C to + 40C. With electrical penlift ...
BD300-4
BD300-4. Four Channel data acquisition recorder with AC power cable, 12 fibre pens, 1 packet of Z-floded paper and operating manual. Input range 1mV - 250 vDC/AC, 1mA - 500mA DC/AC, Thermcouples (Types, B, E, J, K, N, R, S, T) & PT100 sensors, sample rate 400Hz, with 250mm chart, max chart speed 50mm second. ...
BD300-6
BD300 6 Channel chart recorder, input range 1mV - 250 vDC/AC, 1mA - 500mA DC/AC, Thermcouples (Types, B, E, J, K, N, R, S, T) & PT100 sensors, sample rate 400Hz, with 250mm chart, max chart speed 50mm second. Built in datalogger, logs direct to PC or internal 1.44mB floppy disc. ...
BD300-8
BD300 8 Channel chart recorder, input range 1mV - 250 vDC/AC, 1mA - 500mA DC/AC, Thermcouples (Types, B, E, J, K, N, R, S, T) & PT100 sensors, sample rate 400Hz, with 250mm chart, max chart speed 50mm second. Built in datalogger, logs direct to PC or internal 1.44mB floppy disc. ...
BK-G4/U6
20mm Residential Diaphragm Gas Meter. Qmax 6m³/h, Qmin 0.04m³/hr. MID Approved, Fireproof to EN1359. 152.4mm Centres. 1" BS 746 to 3/4" BSP unions included. ...
BK-G4/U6-PULSE
20mm Residential Diaphragm Gas Meter. Qmax 6m³/h, Qmin 0.04m³/hr. MID Approved, Fireproof to EN1359. 152.4mm Centres. 1" BS 746 to 3/4" BSP unions included. Fitted with IN-Z61 Pulse transmitter output (100:1 m³) for data to be displayed and logged remotely. ...
309010.0014
Adapter cable Binder to plug-in terminals for K107 programming kit to enable programming of series 30 pressure transmitters with flying leads. ...
GD-24
GEN II radio transmitter for four external K-Type/T-Type thermocouple probes with display. Range -200 to +200°C, Resolution 0.1°C and Accuracy ±0.3°C. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display. ...
GS-CO2
GS-CO2 Carbon Dioxide NDIR Sensor. Measurement Range: 0 to 9999ppm. Accuracy ±0.5%, +30ppm (in range of 0 to 5000ppm), 3 min response time. 6 Byte record length, 297 days logging to internal memory of GL100 unit with a 30 second sampling interval. The GS-CO2 will require a power capacity of 1A and will require a suitable USB power supply. This sensor cannot be powered by the internal batteries of the GL100. ...
OCEAN 5501-1508
OceanDISP- Programming lead ...
WALLBOX
Wall mounting enclosure, complete with SPC4 ...
BMCM High-Performance USB DAQ System – USB-AD16F
The USB-AD16F features 16 Analogue Inputs (selectable ranges of ±1V, ±2V, ±5V, ±10V, with a 250kHz Sampling rate and 16 Bit resolution), 2 Analogue Outputs (10V, with 16 bit resolution), 4 digital inputs and 4 digital outputs (first can be configured as a 19-bit counter) all connected to a PC via a USB connection. Up to 127 devices can be integrated together. Units included galvanic isolation to protect both the connected PC and the analogue ...
GD-24AL
GEN II radio transmitter for four external K/T Type Thermocouple probe with visual and delayed alarm (High and Low alarm level configured using DARCA software). Temperature Range -200 to +200°C, Resolution 0.1°C and Accuracy ±0.3°C. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display. ...
BP16
Backplane for MAL miniature amplifiers: Up to 16 measuring amplifiers, converters, or any other function modules can be integrated in the BP16. If installed close to the signal, it provides for high interference resistance. Ideal for remote signal conditioning of passive sensors. ...
BP2
Connection backplane for qty 2 MAL miniature amplifiers ...
BP2-BOX
Connection backplane for qty 2 MAL miniature amplifiers fitted in IP65 weatherproof box. ...
GD-24H
GEN II radio transmitter for four external K/N Type Thermocouple probe. Temperature Range -200 to +1,200°C (K Type) & -200 to +1,300°C (N Type), Resolution 0.5°C and Accuracy ±2°C. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display. ...
GD-24R
GEN II radio transmitter for four external R Type Thermocouple probe. Temperature Range -200 to +2,000°C, Resolution 0.5°C and Accuracy ±2°C. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display. ...
C30X0-G10F-H6F-36
36-inch Development Interface Cable for the MS-IMU3020 Inertial Measurements Sensors. Includes Harwin G125-2041096L0 connector and Hirose HR30-6P-6S termination connector. Cable jacket Silicone Rubber with FEP wire insulation and Stycast 2651, catalyst 9 Encapsulated IMU connector. Total length 36 inches. ...
C30X0-G10F-PTL-08
8-inch Unterminated Interface Cable for the MS-IMU3020 Inertial Measurements Sensors. Includes Harwin G125-2041096L0 connector and flying leads. Cable jacket Silicone Rubber with FEP wire insulation and Stycast 2651, catalyst 9 Encapsulated IMU connector. Total length 8 inches. Part No. MP00063-003 ...
C30X0-G10F-PTL-12
12-inch Unterminated Interface Cable for the MS-IMU3020 Inertial Measurements Sensors. Includes Harwin G125-2041096L0 connector and flying leads. Cable jacket Silicone Rubber with FEP wire insulation and Stycast 2651, catalyst 9 Encapsulated IMU connector. Total length 12 inches. Part No. MP00063-004 ...
BATT-BACKUP-3.2AH-12V
Battery backup kit comprising of 3.2AH 12v gel cell battery, and inline mains charger. Fitted in ABS wall mount enclosure with mains input terminals and DC O/P terminals. ...
Waterproof 8-pin plug connector with 100m of pre-wired high quality yellow signal cable with 8 wires and a shield covered with black sleeve. Suitable for: For SMP, SGR and SUV5 Smart Radiometers, plus CMP21 (PT100), CMP22 (PT100), CGR3 (PT100), CGR4 (PT100), CHP1, CNR4, UVS, CSD3 ...
One Channel Flatbed Chart Recorder, 200 mm chart roll, 14 measuring voltage ranges from 1 mV to 20 V, (fixed and variable), differential input(s), signals up to 5 Hz, 16 chart speeds from 0.1 mm / min to 20 mm / sec, left or right adjustable zero, shrouded safety input ...
Dual Channel Flatbed Chart Recorder, 200 mm chart roll, 14 measuring voltage ranges from 1 mV to 20 V, (fixed and variable), differential input(s), signals up to 5 Hz, 16 chart speeds from 0.1 mm / min to 20 mm / sec, left or right adjustable zero, shrouded safety input ...
BD300-4. Four Channel data acquisition recorder with AC power cable, 12 fibre pens, 1 packet of Z-floded paper and operating manual. Input range 1mV - 250 vDC/AC, 1mA - 500mA DC/AC, Thermcouples (Types, B, E, J, K, N, R, S, T) & PT100 sensors, sample rate 400Hz, with 250mm chart, ...
BD300 6 Channel chart recorder, input range 1mV - 250 vDC/AC, 1mA - 500mA DC/AC, Thermcouples (Types, B, E, J, K, N, R, S, T) & PT100 sensors, sample rate 400Hz, with 250mm chart, max chart speed 50mm second. Built in datalogger, logs direct to PC or internal 1.44mB floppy ...
BD300 8 Channel chart recorder, input range 1mV - 250 vDC/AC, 1mA - 500mA DC/AC, Thermcouples (Types, B, E, J, K, N, R, S, T) & PT100 sensors, sample rate 400Hz, with 250mm chart, max chart speed 50mm second. Built in datalogger, logs direct to PC or internal 1.44mB floppy ...
20mm Residential Diaphragm Gas Meter. Qmax 6m³/h, Qmin 0.04m³/hr. MID Approved, Fireproof to EN1359. 152.4mm Centres. 1" BS 746 to 3/4" BSP unions included. Fitted with IN-Z61 Pulse transmitter output (100:1 m³) for data to be displayed and logged remotely. ...
GEN II radio transmitter for four external K-Type/T-Type thermocouple probes with display. Range -200 to +200°C, Resolution 0.1°C and Accuracy ±0.3°C. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display. ...
GS-CO2 Carbon Dioxide NDIR Sensor. Measurement Range: 0 to 9999ppm. Accuracy ±0.5%, +30ppm (in range of 0 to 5000ppm), 3 min response time. 6 Byte record length, 297 days logging to internal memory of GL100 unit with a 30 second sampling interval. The GS-CO2 will require a power capacity of ...
The USB-AD16F features 16 Analogue Inputs (selectable ranges of ±1V, ±2V, ±5V, ±10V, with a 250kHz Sampling rate and 16 Bit resolution), 2 Analogue Outputs (10V, with 16 bit resolution), 4 digital inputs and 4 digital outputs (first can be configured as a 19-bit counter) all connected to a PC ...
GEN II radio transmitter for four external K/T Type Thermocouple probe with visual and delayed alarm (High and Low alarm level configured using DARCA software). Temperature Range -200 to +200°C, Resolution 0.1°C and Accuracy ±0.3°C. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display. ...
Backplane for MAL miniature amplifiers: Up to 16 measuring amplifiers, converters, or any other function modules can be integrated in the BP16. If installed close to the signal, it provides for high interference resistance. Ideal for remote signal conditioning of passive sensors. ...
GEN II radio transmitter for four external K/N Type Thermocouple probe. Temperature Range -200 to +1,200°C (K Type) & -200 to +1,300°C (N Type), Resolution 0.5°C and Accuracy ±2°C. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display. ...
GEN II radio transmitter for four external R Type Thermocouple probe. Temperature Range -200 to +2,000°C, Resolution 0.5°C and Accuracy ±2°C. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display. ...
36-inch Development Interface Cable for the MS-IMU3020 Inertial Measurements Sensors. Includes Harwin G125-2041096L0 connector and Hirose HR30-6P-6S termination connector. Cable jacket Silicone Rubber with FEP wire insulation and Stycast 2651, catalyst 9 Encapsulated IMU connector. Total length 36 inches. ...
Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.