6314018
Replacement cell for OLCT100XP H2S 0-100%..
TP-400-OQ
Stainless Steel Thermal Barrier for OQ610-S data loggers. Dimensions: 500mm x 560mm x 405mm, weight 65Kg approx. Thermal capacity of 22 Hrs at 200°C or 3 Hrs at 950°C (max internal temp 70°C)...
GD-10
GEN II radio transmitter with an integrated digital relative humidity and temperature probe and display. Temperature Range -30 to +65°C, Resolution 0.1°C and Accuracy ±0.4°C (-5 to +40°C). RH Range 0-100%RH, Resolution 0.1% and Accuracy ±2% (10-90%RH). Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display...
6350A2A
Profibus PA/Foundation Fieldbus transmitter with a 9-32vDC power supply. Single channel unit for RTD, TC, Linear resistance, potentiometer and bipolar mV measurement, producing a bus communication output via Profibus PA or Foundation Fieldbus. Can be mounted vertically or horizontally on a DIN rail...
6350A2B
Profibus PA/Foundation Fieldbus transmitter with a 9-32vDC power supply. Dual channel unit for RTD, TC, Linear resistance, potentiometer and bipolar mV measurement, producing a bus communication output via Profibus PA or Foundation Fieldbus. Can be mounted vertically or horizontally on a DIN rail...
6350B2A
Intrinsically safe Profibus PA/Foundation Fieldbus transmitter with a 9-32vDC power supply. Single channel unit for RTD, TC, Linear resistance, potentiometer and bipolar mV measurement, producing a bus communication output via Profibus PA or Foundation Fieldbus. Can be mounted vertically or horizontally on a DIN rail...
GD-11
Transmitters with built in digital RH and temperature sensor + external thermistor (-40 to +70C) with display..
6350B2B
Intrinsically safe Profibus PA/Foundation Fieldbus transmitter with a 9-32vDC power supply. Dual channel unit for RTD, TC, Linear resistance, potentiometer and bipolar mV measurement, producing a bus communication output via Profibus PA or Foundation Fieldbus. Can be mounted vertically or horizontally on a DIN rail...
65-56-491
1/2 inch Brass nipple suitable for PT500 direct sensors...
65-56-492
3/4 inch Brass nipple suitable for PT500 direct sensors...
65-57-314
1/2 inch Stainless Steel sensor pocket suitable for 5.8mm diameter PT500 pocket sensors. Pocket length 140mm...
65-57-324
1/2 inch Stainless Steel sensor pocket suitable for 5.8mm diameter PT500 pocket sensors. Pocket length 65mm...
65-57-327
1/2 inch Stainless Steel sensor pocket suitable for 5.8mm diameter PT500 pocket sensors. Pocket length 90mm...
7002
Stainless Steel retention clip for use with 11 point relay socket. Necessary in environments with strong vibrations...
7230382
Neodymium Iron Boron, Bright Nickel-plated permanent magnet. 10mm diameter, 5mm height...
GD-13E
Transmitters for use with external probes - Wired socket for 1 x RHT-10D RH/T probe with display..
GD-13G
GEN II radio transmitter with wired socket suitable for an HC2-S3 Temperature and Humidity Probe. integrated temperature and relative humidity probe. Temperature Range -40 to +60 C, and Accuracy 0.3 C at 23 C. Humidity Range 0-100% and Accuracy 1.5% at 23 C. Supplied with 4 x AA Alkaline batteries,..
GD-13J-EE08
GENII transmitter fitted with EE08 temp/RH probe, range 0-100% RH, -40 to +80 deg C. fitted with 2 metres of cable from probe to transmitter...
832-757
Stainless Steel wall bracket for the Printing Temperature Recorder..
GD-14E
Transmitters for use with external probes - Wired socket for 1 x RHT-10D RH/T probe and 2 x thermistor temperature probes (-40 to +70C) with display..
8422
SIM pin for 5350. Required if the simulation mode function is to be used...
8806020480
Programmable TxRail, single channel temperature transmitter. Suitable for PT100, Thermocouple (Type J, K, T, E, N, R or S), 0-50mV, linear resistance and mA input. Transmitter generates a 2-wire 0-10vDC output which is linear to the measured input signal range. Power Supply 18 to 35vDC across transmitter. Can be mounted..
8813001000
LogBox-DA IP65 Data Logger, 1 Analogue (0-50mV 0-10v and 4-20mA inputs) & 1 Digital input for pulse inputs (NPN or PNP up to 4 KHz) or dry contact (up to 20 Hz), with 32,000 rdg memory, battery life up to 3 years. Sensor external power switch. External connection via IP65..
8813001010
LogBox-DA IP67 Data Logger, 1 Analogue (0-50mV 0-10v and 4-20mA inputs) & 1 Digital input for pulse inputs (NPN or PNP up to 4 KHz) or dry contact (up to 20 Hz), with 32,000 rdg memory, battery life up to 3 years. Sensor external power switch. External connection via IP67..