748-521

Type T slimline, 6.2mm thick DIN rail mount thermocouple transmitter, range -50 to + 100 deg c, power supply 19.2 - 30v DC, accuracy 0.1%, output 4-20mA ...

860-860

Legionnaires Thermometer Kit. Each kit contains: Therma 1 thermometer; penetration probe; precision ribbon sufrace probe; PTFE wire probe; countdown timer; One tub UniWipes; ABS carrying case. ...

8811612420

DigiRail Connect DMIX Ethernet I/O Module. 8 Digital Inputs: High Logic Level (1): >2.2V, Low Logic Level (0): <1.5V; Pulse Counter; Digital State (NPN, PNP or dry contact). 8 Transistor Sourcing Digital Outputs, Actuation Modes:: Logical State; Pulse Duration; or Pulse Train. Power Supply 10-36vDC. Modules are DIN Rail mountable ...

8818040031

FTR DIN Rail Transmitter Power Supply. Input 100-240vAC, Output 24vDC at 3W, 600V Isolation. IP40 grey polymide enclosure suitable for connection to a 35mm DIN Rail. ...

8830007000

PT100 temperature sensor with a 6mm diameter 316 Stainless Steel probe with 50mm probe length and ½" BSP thread connection. Suitable for temperatures from -50 up to 300°C. Transmitter housing suitable for any standard head mounted transmitter. Cable gland access for remote connection ...

9106A1A

Single channel isolated HART transparent repeater, 4-20mA input, 4ƒ-20 mA output, power supply 19.2 - 31.2, SIL2 certified to IEC 61508 ...

9106B1A

Single channel isolated HART transparent repeater ATEX approved I.S., 4-20mA input, 4ƒ-20 mA output, power supply 19.2 - 31.2, SIL2 certified to IEC 61508 ...

9202A1A

Pulse isolator, 1 channel with NAMUR/contact input frequency range 0-5 KHz, and opto output, SIL 2, isolated, 19.2 - 31.2 VDC supply. With cable fault check (LFD) function. ...

9202B1A

Pulse isolator, I.S ATEX approved 1 channel with NAMUR/contact input frequency range 0-5 KHz, and opto output, SIL 2, isolated, 19.2 - 31.2 VDC supply. ...

9203A1A

Solenoid and alarm driver, 1 channel driver output, digital switch input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output. ...

9203B1A

Solenoid and alarm driver, ATEX approved 1 channel driver output, digital switch input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output. ...

AC Voltage Transducers

DIN Rail mounted AC voltage transducers used for converting AC voltage to a proportional mA or voltage output. Versions available for average sensing and true RMS, plus unit for monitoring deviations in narrow bands around a nominal voltage. Options available for auxiliary or self powered supplies. Adjustable span and zero ...

AKF390B

3 Axis MEMS Accelerometer with a voltage output. 0-5V output for X, Y and Z axis. Ranges from ±2g to ±40g. M12 5-pin connector. Power Supply 9-36vDC. Dimensions: 34.4 x 34.4 x 38mm. Operating Temperature: -40 to +85°C. ...

AKF392B

3 Axis MEMS Accelerometer with a Modbus output. RS232, RS485 and TTL options. Ranges from ±2g to ±40g. M12 5-pin connector. Power Supply 9-36vDC. Dimensions: 34.4 x 34.4 x 38mm. Operating Temperature: -40 to +85°C. ...

AMC232LAN01

Serial to ethernet converter,with serial 9 pin D connector, and ethernet socket, power supply 7.5 - 24v DC. ...

AML-M

Miniature LVDT displacement transducer, stainless steel body and rod, operating temperature -30 to +85 deg. C, sealed to IP40. ranges +/- 0.25 to +/-75mm, linearity less than 0.5% FSD. ...

ATM/N/EX

ATMNEX intrinsically safe submersible depth sensor, ranges 0-0.1 to 0-25 barG, with stainless steel body, certified EEx ia IIC T4...T6 ...

ATM/N/T Depth Sensor

ATM/N/T Submersible Depth & Temperature Sensor. Pressure ranges from 1 to 250mWC. Supply voltage 15-30vDC. Operating temperature -5 to 80°C. ...

ATM/NC Level Transmitter

ATM/NC Submersible Depth Sensor suitable for corrosive media with a PVDF body. Pressure ranges from 1 to 250mWC. Supply voltage 15-30vDC. Operating temperature -5 to 80°C. ...

BGN Variable Area Flow Meters

Model BGN flow meter, variable area type, stainless steel body, with visual indicator. Accuracy ±2 %. With ANSI 150 flanges, sizes ½" to 4". Simple device suitable for use in a hazardous area. ...

BL-1D

HygroLog BL-1D datalogger with an integrated temperature, humidity and barometric pressure sensors and LED display. The BL-1D has an internal memory for up to 64,000 data points with adjustable log intervals (30secs to 24Hrs). Measuring range: -20 to +70°C, 0 to 100%RH and 300 to 1100 hPa. Accuracy ±0.3°C, ±3%RH ...

CAB4COREHT

High Temperature Silicone Cable, 4 Core, 50m Reel ...

Cable Glands

Compression type cable glands provide sealing and retention for a wide range of cables for general indoor and outdoor applications. ...

CDI 5200

Compressed air flow meter, for pipe sizes ½ to 1½ inch , clamp on type, accuracy 5% of RDG +1% FSD, operating temperature -7-49°C. With 4-20mA, pulse outputs. Optional MODBUS RTU RS485 O/P ...
Edit Content

748-521

Type T slimline, 6.2mm thick DIN rail mount thermocouple transmitter, range -50 to + 100 deg c, power supply 19.2 - 30v DC, accuracy 0.1%, output 4-20mA ...

860-860

Legionnaires Thermometer Kit. Each kit contains: Therma 1 thermometer; penetration probe; precision ribbon sufrace probe; PTFE wire probe; countdown timer; One tub UniWipes; ABS carrying case. ...

8811612420

DigiRail Connect DMIX Ethernet I/O Module. 8 Digital Inputs: High Logic Level (1): >2.2V, Low Logic Level (0): <1.5V; Pulse Counter; Digital State (NPN, PNP or dry contact). 8 Transistor Sourcing Digital Outputs, Actuation Modes:: Logical State; Pulse Duration; or Pulse Train. Power Supply 10-36vDC. Modules are DIN Rail mountable with a working temperature of -20 to 60°C. Dimensions: 100 x 30.8 x 110.2mm. RJ45 Ethernet Connection, Micro USB and RS485 Modbus Terminals. NXperience software ...

8818040031

FTR DIN Rail Transmitter Power Supply. Input 100-240vAC, Output 24vDC at 3W, 600V Isolation. IP40 grey polymide enclosure suitable for connection to a 35mm DIN Rail. ...

8830007000

PT100 temperature sensor with a 6mm diameter 316 Stainless Steel probe with 50mm probe length and ½" BSP thread connection. Suitable for temperatures from -50 up to 300°C. Transmitter housing suitable for any standard head mounted transmitter. Cable gland access for remote connection ...

9106A1A

Single channel isolated HART transparent repeater, 4-20mA input, 4ƒ-20 mA output, power supply 19.2 - 31.2, SIL2 certified to IEC 61508 ...

9106B1A

Single channel isolated HART transparent repeater ATEX approved I.S., 4-20mA input, 4ƒ-20 mA output, power supply 19.2 - 31.2, SIL2 certified to IEC 61508 ...

9202A1A

Pulse isolator, 1 channel with NAMUR/contact input frequency range 0-5 KHz, and opto output, SIL 2, isolated, 19.2 - 31.2 VDC supply. With cable fault check (LFD) function. ...

9202B1A

Pulse isolator, I.S ATEX approved 1 channel with NAMUR/contact input frequency range 0-5 KHz, and opto output, SIL 2, isolated, 19.2 - 31.2 VDC supply. ...

9203A1A

Solenoid and alarm driver, 1 channel driver output, digital switch input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output. ...

9203B1A

Solenoid and alarm driver, ATEX approved 1 channel driver output, digital switch input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output. ...

AC Voltage Transducers

DIN Rail mounted AC voltage transducers used for converting AC voltage to a proportional mA or voltage output. Versions available for average sensing and true RMS, plus unit for monitoring deviations in narrow bands around a nominal voltage. Options available for auxiliary or self powered supplies. Adjustable span and zero with ±0.25% accuracy. ...

AKF390B

3 Axis MEMS Accelerometer with a voltage output. 0-5V output for X, Y and Z axis. Ranges from ±2g to ±40g. M12 5-pin connector. Power Supply 9-36vDC. Dimensions: 34.4 x 34.4 x 38mm. Operating Temperature: -40 to +85°C. ...

AKF392B

3 Axis MEMS Accelerometer with a Modbus output. RS232, RS485 and TTL options. Ranges from ±2g to ±40g. M12 5-pin connector. Power Supply 9-36vDC. Dimensions: 34.4 x 34.4 x 38mm. Operating Temperature: -40 to +85°C. ...

AMC232LAN01

Serial to ethernet converter,with serial 9 pin D connector, and ethernet socket, power supply 7.5 - 24v DC. ...

AML-M

Miniature LVDT displacement transducer, stainless steel body and rod, operating temperature -30 to +85 deg. C, sealed to IP40. ranges +/- 0.25 to +/-75mm, linearity less than 0.5% FSD. ...

ATM/N/EX

ATMNEX intrinsically safe submersible depth sensor, ranges 0-0.1 to 0-25 barG, with stainless steel body, certified EEx ia IIC T4...T6 ...

ATM/N/T Depth Sensor

ATM/N/T Submersible Depth & Temperature Sensor. Pressure ranges from 1 to 250mWC. Supply voltage 15-30vDC. Operating temperature -5 to 80°C. ...

ATM/NC Level Transmitter

ATM/NC Submersible Depth Sensor suitable for corrosive media with a PVDF body. Pressure ranges from 1 to 250mWC. Supply voltage 15-30vDC. Operating temperature -5 to 80°C. ...

BGN Variable Area Flow Meters

Model BGN flow meter, variable area type, stainless steel body, with visual indicator. Accuracy ±2 %. With ANSI 150 flanges, sizes ½" to 4". Simple device suitable for use in a hazardous area. ...

BL-1D

HygroLog BL-1D datalogger with an integrated temperature, humidity and barometric pressure sensors and LED display. The BL-1D has an internal memory for up to 64,000 data points with adjustable log intervals (30secs to 24Hrs). Measuring range: -20 to +70°C, 0 to 100%RH and 300 to 1100 hPa. Accuracy ±0.3°C, ±3%RH & ±3hPa. BL-1D is powered by a single CR2 battery. IP67 housing, dimensions 90 x 60 x 23mm. Communications via mini USB port. Units are ...

CAB4COREHT

High Temperature Silicone Cable, 4 Core, 50m Reel ...

Cable Glands

Compression type cable glands provide sealing and retention for a wide range of cables for general indoor and outdoor applications. ...

CDI 5200

Compressed air flow meter, for pipe sizes ½ to 1½ inch , clamp on type, accuracy 5% of RDG +1% FSD, operating temperature -7-49°C. With 4-20mA, pulse outputs. Optional MODBUS RTU RS485 O/P ...

748-521

Type T slimline, 6.2mm thick DIN rail mount thermocouple transmitter, range -50 to + 100 deg c, power supply 19.2 - 30v DC, accuracy 0.1%, output 4-20mA ...

860-860

Legionnaires Thermometer Kit. Each kit contains: Therma 1 thermometer; penetration probe; precision ribbon sufrace probe; PTFE wire probe; countdown timer; One tub UniWipes; ABS carrying case. ...

8811612420

DigiRail Connect DMIX Ethernet I/O Module. 8 Digital Inputs: High Logic Level (1): >2.2V, Low Logic Level (0): <1.5V; Pulse Counter; Digital State (NPN, PNP or dry contact). 8 Transistor Sourcing Digital Outputs, Actuation Modes:: Logical State; Pulse Duration; or Pulse Train. Power Supply 10-36vDC. Modules are DIN Rail mountable ...

8818040031

FTR DIN Rail Transmitter Power Supply. Input 100-240vAC, Output 24vDC at 3W, 600V Isolation. IP40 grey polymide enclosure suitable for connection to a 35mm DIN Rail. ...

8830007000

PT100 temperature sensor with a 6mm diameter 316 Stainless Steel probe with 50mm probe length and ½" BSP thread connection. Suitable for temperatures from -50 up to 300°C. Transmitter housing suitable for any standard head mounted transmitter. Cable gland access for remote connection ...

9106A1A

Single channel isolated HART transparent repeater, 4-20mA input, 4ƒ-20 mA output, power supply 19.2 - 31.2, SIL2 certified to IEC 61508 ...

9106B1A

Single channel isolated HART transparent repeater ATEX approved I.S., 4-20mA input, 4ƒ-20 mA output, power supply 19.2 - 31.2, SIL2 certified to IEC 61508 ...

9202A1A

Pulse isolator, 1 channel with NAMUR/contact input frequency range 0-5 KHz, and opto output, SIL 2, isolated, 19.2 - 31.2 VDC supply. With cable fault check (LFD) function. ...

9202B1A

Pulse isolator, I.S ATEX approved 1 channel with NAMUR/contact input frequency range 0-5 KHz, and opto output, SIL 2, isolated, 19.2 - 31.2 VDC supply. ...

9203A1A

Solenoid and alarm driver, 1 channel driver output, digital switch input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output. ...

9203B1A

Solenoid and alarm driver, ATEX approved 1 channel driver output, digital switch input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output. ...

AC Voltage Transducers

DIN Rail mounted AC voltage transducers used for converting AC voltage to a proportional mA or voltage output. Versions available for average sensing and true RMS, plus unit for monitoring deviations in narrow bands around a nominal voltage. Options available for auxiliary or self powered supplies. Adjustable span and zero ...

AKF390B

3 Axis MEMS Accelerometer with a voltage output. 0-5V output for X, Y and Z axis. Ranges from ±2g to ±40g. M12 5-pin connector. Power Supply 9-36vDC. Dimensions: 34.4 x 34.4 x 38mm. Operating Temperature: -40 to +85°C. ...

AKF392B

3 Axis MEMS Accelerometer with a Modbus output. RS232, RS485 and TTL options. Ranges from ±2g to ±40g. M12 5-pin connector. Power Supply 9-36vDC. Dimensions: 34.4 x 34.4 x 38mm. Operating Temperature: -40 to +85°C. ...

AMC232LAN01

Serial to ethernet converter,with serial 9 pin D connector, and ethernet socket, power supply 7.5 - 24v DC. ...

AML-M

Miniature LVDT displacement transducer, stainless steel body and rod, operating temperature -30 to +85 deg. C, sealed to IP40. ranges +/- 0.25 to +/-75mm, linearity less than 0.5% FSD. ...

ATM/N/EX

ATMNEX intrinsically safe submersible depth sensor, ranges 0-0.1 to 0-25 barG, with stainless steel body, certified EEx ia IIC T4...T6 ...

ATM/N/T Depth Sensor

ATM/N/T Submersible Depth & Temperature Sensor. Pressure ranges from 1 to 250mWC. Supply voltage 15-30vDC. Operating temperature -5 to 80°C. ...

ATM/NC Level Transmitter

ATM/NC Submersible Depth Sensor suitable for corrosive media with a PVDF body. Pressure ranges from 1 to 250mWC. Supply voltage 15-30vDC. Operating temperature -5 to 80°C. ...

BGN Variable Area Flow Meters

Model BGN flow meter, variable area type, stainless steel body, with visual indicator. Accuracy ±2 %. With ANSI 150 flanges, sizes ½" to 4". Simple device suitable for use in a hazardous area. ...

BL-1D

HygroLog BL-1D datalogger with an integrated temperature, humidity and barometric pressure sensors and LED display. The BL-1D has an internal memory for up to 64,000 data points with adjustable log intervals (30secs to 24Hrs). Measuring range: -20 to +70°C, 0 to 100%RH and 300 to 1100 hPa. Accuracy ±0.3°C, ±3%RH ...

CAB4COREHT

High Temperature Silicone Cable, 4 Core, 50m Reel ...

Cable Glands

Compression type cable glands provide sealing and retention for a wide range of cables for general indoor and outdoor applications. ...

CDI 5200

Compressed air flow meter, for pipe sizes ½ to 1½ inch , clamp on type, accuracy 5% of RDG +1% FSD, operating temperature -7-49°C. With 4-20mA, pulse outputs. Optional MODBUS RTU RS485 O/P ...