190PD-E-WPG-HIRE
190PDE Portable Clamp-on Heat Meter. WPG transducer suitable for pipe sizes: 15mm to 300mm, temperature range: -30 to 105°C (intermittent use to 130°C). Electronics: Portable mount IP54 Display: Rate of flow, totalised flow, velocity. Units selectable via the keypad. Data Logger: Built-in, 120000 readings. Saved as text and graph. RS232..
190PDE Portable Ultrasonic Non-Invasive Heat Meter Hire
The 190PDE is a heat meter that utilises the 190PD ultrasonic flow meter and a pair of temperature probes to provide a convenient portable heat meter suitable for short term non-invasive heat meter and flow monitoring. Transducers provide a wide pipe diameter range from as small as 15mm up to..
TR525-M
9.66 inch Tipping Bucket Rain Gauge, resolution 1 pulse per 0.1mm. Anodised aluminium collector..
1GT101DC
Hall effect gear tooth sensor. Supply: 4.5 to 24VDC. Output 40mA sinking switch (open collector). 100kHz operating speed. -40 to +150°C temperature range...
RC250-MOD
GEN II Receiver logger for up to 160 channels with a serial Modbus output. 6 pin Mini DIN socket for polled data output, direct connection to a PC or Ethernet Connection via MOXA D311 adaptor. LCD display and 24 hour built-in standby battery (6 x NiMh AA batteries). Supplied with..
2279 AC/DC Transmitter
The 2279 AC/DC Transmitter is suitable for measuring AC voltage in the range of 0.5 to 250 VRMS sinusoidal voltages and current measurements up to 1 ARMS with a direct connection to the unit and higher current ranges with an external shunt. Standard analogue outputs are selectable using DIP Switches..
2284 Isolation Amplifier
Galvanically separated input, output, and supply ~ Bipolar current / voltage input Signal conversion ~ Current and voltage output 24 VDC or universally supplied Applicable in PELV/SELV circuits..
242428-1313
POLILYTE Plus ARC pH sensor. Power supply, 7-30vDC, measuring range 0 to 14 pH with zero point +/-20mV at 25 C (factory calibration). Each sensor provides two programmable 4-20mA output for pH and temperature plus RS485 Modbus RTU output via VP 8.0 socket head. Glass shaft with Viton seals and..
242428-1323
POLILYTE Plus ARC pH sensor. Power supply, 7-30vDC, measuring range 0 to 14 pH with zero point +/-20mV at 25 C (factory calibration). Each sensor provides two programmable 4-20mA output for pH and temperature plus RS485 Modbus RTU output via VP 8.0 socket head. Glass shaft with Viton seals and..
242428-1333
POLILYTE Plus ARC pH sensor. Power supply, 7-30vDC, measuring range 0 to 14 pH with zero point +/-20mV at 25 C (factory calibration). Each sensor provides two programmable 4-20mA output for pH and temperature plus RS485 Modbus RTU output via VP 8.0 socket head. Glass shaft with Viton seals and..
2643853
XR 13 pack of 5 fibre pens, Red long, for channel 2 of BD 12 / 12E..
2643858
XR 13 pack of 5 fibre pens, Black long, for channel 2 of BD 12 / 12E..
2643908
XR 12 pack of 5 fibre pens, Black short..
2643909
XR 12 pack of 5 fibre pens, Red short..
2643918
XR 9 10 rolls of chart paper, length 25 m, zero left..
2643962
XR 18 10 rolls of chart paper, length 25 m, zero right..
294-900
Thermadata Stainless Steel Data Logger with Integrated Temperature Sensor. Temperature Range: -20 to +125°C. Memory 16,000 readings. Logging rate from 1 to 255 minutes with delayed start and individual 12 character ID. 3.6V 2/3 AA Lithium Battery provides 3 years operation. Loggers are supplied with USB cable and ThermaData Studio..
294-930
Thermadata Stainless Steel Data Logger with Ø3.3 x 50mm Penetration Temperature Probe. Temperature Range: -20 to +125°C. Memory 16,000 readings. Logging rate from 1 to 255 minutes with delayed start and individual 12 character ID. 3.6V 2/3 AA Lithium Battery provides 3 years operation. Loggers are supplied with USB cable..
294-931
Thermadata Stainless Steel Data Logger with Ø4.5 x 100mm Penetration Temperature Probe. Temperature Range: -20 to +125°C. Memory 16,000 readings. Logging rate from 1 to 255 minutes with delayed start and individual 12 character ID. 3.6V 2/3 AA Lithium Battery provides 3 years operation. Loggers are supplied with USB cable..
294-932
Thermadata Stainless Steel Data Logger with Ø4.5 x 150mm Penetration Temperature Probe. Temperature Range: -20 to +125°C. Memory 16,000 readings. Logging rate from 1 to 255 minutes with delayed start and individual 12 character ID. 3.6V 2/3 AA Lithium Battery provides 3 years operation. Loggers are supplied with USB cable..
294-933
Thermadata Stainless Steel Data Logger with Ø4.5 x 200mm Penetration Temperature Probe. Temperature Range: -20 to +125°C. Memory 16,000 readings. Logging rate from 1 to 255 minutes with delayed start and individual 12 character ID. 3.6V 2/3 AA Lithium Battery provides 3 years operation. Loggers are supplied with USB cable..
RP250GD
GEN II Radio Repeater. Supplied with AC power supply, 24 hour built-in standby battery (6 x NiMh AA batteries), antenna and integral LCD display. Repeater will extending the effective range of GEN II receiver units and signal paths of transmitters in poor coverage areas...
0367703
Shading Ball Assembly. Including 2 shading balls on adjustable rods, large top mounting and second side mounting plate...
11220006
ComNav G2 GNSS Satellite with Compass Differential GPS (DGPS) correction and 6m cable. Output: NMEA2000. Update rate: Heading & position updates at up to 20 times per second, and can operate at sustained turn rates up to 90° per second. Power Supply 10 to 36vDC (240mA @ 12vDC). The G2..