Description
The Easy Duo pack includes an MX16 controller, OLCT10N detector for CO (Carbon Monoxide) and fitted with 10 metre cable. The MX16 controller comes pre-configured from the factory. So, you don’t need to get any configuration software for the installation. The OLCT10N’s use a specific RS485 for digital communication and can be replaced without the need for reconfiguration.
Features
- Single channel gas controller
- Easy Duo pack comes with MX16 controller and OLCT10N gas detector
- OLCT10N detector with 10m of cable.
- Low Cost and Easy to Install
- Integrated Relays
- Easy to read large graphic and multi-language LCD back-lit display
- Soft-touch Keys for Embedded Menus
Applications
- Monitoring levels of CO in enclosed areas.
- Gas Leaks in Boiler Rooms
- Gas Releases in Battery Charging Areas
- Water Water Treatment Plants
- Petrochemical Industry
- Laboratories
Specifications
General Specifications
Dimensions: | 265 x 266 x 96mm |
Ingress protection | IP55 |
Cable entries:
|
3 M16 cable glands, 4 to 8 mm² (8 to 11 AWG) outer diameter cable 2 M20 cable glands, 6 to 12 mm² (7 to 9 AWG) outer diameter cable |
Display:
|
LCD back-lit display + smart keys Display in grayscale in case of fault Bar graph with alarm threshold |
Visual indicators: | 6 LEDs, 5 LEDs for Detector Status Line, 1 LED fault indicator and 1 LED Power Condition |
Buttons: | 5 smart keys, 1 audible alarm accept/reset button |
Operating Environment: | Temp: -20°C to +50°C, Humidity 5 – 95%RH |
Power Supply: | 100-240vAC 50-60 Hz (35W) |
Consumption: | 250 mA max (without captor) |
Alarms
Per channel: |
2 alarm levels (AL1 and AL2) + 1 Fault |
Accessible and modifiable alarm threshold Al1 and Al2, manual acknowledgement | |
On-board relays:
|
2 alarm relays 1 fault relay (non-configurable) Dry Contact Relay, RCT, 250vAC, 5A |
OLCT10N Gas Detector
The OLCT10N is a digital gas detector designed for detection of the most common gases in commercial and light industrial applications. The OLCT10N is IP65 and ATEX 3 GD certified, for use in ATEX 2 and 22 zones, and is water- and dustproof.
Gas Detected: | CO (Carbon Monoxide) |
Range: | 0-300ppm |
Output: |
RS-485 Modbus communication, proprietary protocol, 9600 Baud |
Cable: | Fitted with 10m, 2 twisted shielded-pair cable |
Dimensions (L x H x W): | 118 x 110 x 60mm |
Enclosure: | IP65, ABS enclosure, UV and shocks resistant |
Approvals: | II 3 GD – IECEx 11.0029X Ex tc IIIC T135°C Dc -20°C<Ta<+55°C Electromagnetic compatibility according to EN50270 |
The Easy Duo pack includes an MX16 controller, OLCT10N detector for CO (Carbon Monoxide and fitted with 10 metre cable. The MX16 controller comes pre-configured from the factory. So, you don’t need to get any configuration software for the installation. The OLCT10N’s use a specific RS485 for digital communication and can be replaced without the need for reconfiguration.