Description
This WindSonic M, Part Number 1405-PK-201. features serial outputs in RS232, RS422 and RS485 with NMEA 0183 or ASCII protocols, analogue outputs and optional heating. Versions without the heating or analogue outputs can be found on the main page linked below.
WindSonic M Ultrasonic Anemometer
Features
- Wind Speed & Direction Sensor
- 0-60m/s (116 knots) Wind Speed
- 0-359° Wind Direction
- WMO Compliant gust wind speed and directions
- Vibration BS EN 60945:2002
- Impact Resistance to UL2219 Class 1
- NMEA Output
- RS485 Modbus RTU Output
- Analogue 0-5V or 4-20mA Output
- Hard anodised Aluminium alloy construction
- Optional heating allow -40°C Operation
- 24 Month Warranty
- Free WindCom Software
Typical Applications
- Data buoys
- Marine vessels
- Ports and harbours
- Offshore helipads
- Road & rail tunnels
- Remote island weather stations
- Coastal weather monitoring stations
Specifications
Wind Speed Range | 0-60m/s (0-116 knots) | |||
Wind Direction | 0-360° (no dead band) | |||
Starting Threshold | 0.01m/s | |||
Accuracy | Wind Speed 2%, Direction 2° @ 12m/s | |||
Resolution | Wind Speed 0.01m/s, Direction 0.1° | |||
Ultrasonic Output Rate | 0.25, 0.5, 1, 2 or 4Hz | |||
Parameters | Speed & Direction or U & V Vectors | |||
Units | m/s, knots, mph, kph, ft/min | |||
Power Supply | 5-30vDC (Output Dependant) | |||
Housing Material | Al Alloy 6061 T6 with Hard Anodised finish | |||
Operating Temperature | -40 to 70°C | |||
Size | 142 x 163mm | |||
Weight | 0.9Kg |
1405-PK-201
Output Options
Heating: | Included and activate on temperature |
Serial Outputs: | RS232, RS422, RS485 and NMEA |
Baud Rates: | 2400 to 38400. |
Anemometer Status: | Supplied as part of standard message |
Power Supply for Heated Variants
DC Power Supply Voltage: | 10 to 30.0vDC. |
AC Power Supply Voltage: | 24V RMS AC ±10 % @50/60Hz. |
12VDC Power Supply: | Allow for 2.2 Amps @ 12V DC (nominal supply), 26W max. |
24VDC Power Supply: | Allow for 4.2 Amps @24v AC or DC (nominal supply) 100W max. |
Standby Heater Current: | Approximately 40mA. |
For optimal performance, especially during initial start-up, a dedicated 24vDC heater supply capable of delivering a minimum of 6 Amps is recommended for the WindSonic M’s heating system for initial heating start-up surges. While the heater supply is electrically isolated from the sensor’s power, it is acceptable to use a common 24vDC source for both, if necessary. It is crucial to ensure that neither the sensor nor the heater supply connections are ever connected to the WindSonic M’s metal casing.
To maintain efficient heating, the length of the heater cable should be kept as short as possible to minimise voltage drops and ensure the anemometer receives the maximum available voltage. If longer cable runs are unavoidable, consider connecting spare wires in parallel to the designated heater pins. This effectively increases the wire gauge, reducing resistance and subsequent voltage drops across the cable.
The heating system in the heated WindSonic M operates autonomously, activated by internal temperature sensors when conditions likely to cause icing are detected. There is no external command to enable or disable the heating; it is continuously active and cycles on and off based on the sensed temperature. To completely disable the heating, the heater power supply must be physically disconnected. As a confirmation of functionality, a one-minute burst of heating will automatically occur upon powering up a heated WindSonic M unit, provided the heater supply is connected. Furthermore, the WindSonic M incorporates reverse polarity protection to prevent damage from incorrect power connections.