CDI 5200 Compressed Air Flow Meter

The CDI5200 series of compressed air flow meter are suitable for small pipe diameters from ½” up to 1½”. The flow meters provide a local display of compressed air flows with 4-20mA and pulse outputs, plus the option of Modbus RTU outputs. The flow meter clamps onto the pipe using two mounting rings that each include a single flow-sensing probe projecting into the pipe through 3/16-in. drilled holes. The meter seals directly to the pipe and therefore required no cutting or welding for installation. Each flow meter is made and calibrated for the specific size of pipe and does not require any setup or adjustment.

Need help finding the right product?

Downloads

CDI5200 Compressed Air Flow Meter

Description

The CDI 5200 is a true thermal-mass flowmeter, adapted for easy installation in existing piping systems. Its large, bright LED display is easy to read from a distance and may be rotated allowing the display to be orientated for vertical or horizontal installations. The 5200 series now comes with the weather-proof enclosure and surge protection that was originally on the 6200 series and make it suitable for outdoor installation. A 4-20mA output and pulse output are standard; with an isolated pulse output module also available for data collection.

The meter measures flow by maintaining one probe warmer than the other. It calculates the mass velocity from the amount of heat required, and then calculates the flow on the basis of pipe area. The displays are configured for the size and dimension of the pipe and the rings will provide a seal on the pipe up to 200psi. The display can show flows in scfm, m³/min and m³/hr; it can also be configured to display daily usage or cumulative usage rather than current flow.

The CDI 5200 meters are commonly used for point-of-use monitoring of compressed air in textile mills, food packaging plants, groundwater remediation, printing plants and bottling plants; they are also widely used for branch-line monitoring.

Features

  • Easy to install
  • No moving parts
  • Weather resistant and surge protected
  • Integral digital display for flow rate
  • 4-20mA and pulse outputs
  • No calibration or setup required
  • User-configurable scaling, filtering and units of measure.
  • Optional RS485 Modbus RTU comms for networking

Optional summing remote display unit with three user modes:

a) Remote display with instantaneous flow rate
b) Summing display with resetting 24 hour flow total
c) Summing display for flow total with manual reset

Specifications

Accuracy: 5% of RDG + 1% FSD at air temperatures from -7 to 49°C
Medias: Compressed air and nitrogen
Operating pressure:
200psig maximum on Sch. 40 steel and Type L copper
Input power: 250mA at 24vDC
Materials exposed to measured fluid: Aluminium, Stainless steel, gold, thermal epoxy and Viton (seal)
Display: Four-digit LED display
Response time: One second to 63 percent of final value

 

 
Model Pipe Diameter Pipe Material SCFM Nm³/min (20°C) Nm³/Hr (20°C)
CDI-5200-05S ½” Sch. 40 Steel 100 2.83 169.9
CDI-5200-07S ¾” Sch. 40 Steel 150 4.25 254.9
CDI-5200-07C ¾” Type L Copper 150 4.25 254.9
CDI-5200-10S 1″ Sch. 40 Steel 200 5.66 339.8
CDI-5200-10C 1″ Type L Copper 200 5.66 339.8
CDI-5200-12S 1¼” Sch. 40 Steel 400 11.33 679.6
CDI-5200-12C 1¼” Type L Copper 300 8.50 474.9
CDI-5200-15S 1½” Sch. 40 Steel 400 11.33 679.6
CDI-5200-15C 1½” Type L Copper 400 11.33 679.6
CDI-5200-25M 25mm Aluminium 200 5.66 339.8
CDI-5200-40M 40mm Aluminium 400 11.33 679.6

 

Pressure Sensing Option

The pressure-sensing (-PSO) option for the CDI 5200 flow meter allows plant managers to monitor pressure throughout an air distribution system along with flow. The pressure sensor is mounted next to the flow-sensing probes. It accesses pipe pressure through a cutout in the gasket that seals the ring to the pipe and there are no additional steps during installation. The pressure signal is provided as a second milliamp output. With this option, both milliamp outputs are non-isolated; they source current to be returned to the meter’s dc-connection. The display can be configured to show the pressure signal, and the pressure signal is also available through the optional wired and wireless serial outputs.

Specifications

Accuracy: ±2psig Max, ±0.5psig @ 68F
Pressure Range: 0 to 145 psi Operating Range
Scaled 0-145psi = 4-20mA

5000-DG

£89.75

Drill guide for all 5200 and 6200 series flow meters.

5200-SRD

£127.57

Summing remote LED display, wall mount has three modes: instantaneous flow rate reading, 24 hour reseting flow total, manual resetting flow total.

5200-05S-BR

£118.10

Set of two blocking rings for resealing pipework when flow meters are removed. Suitable for CDI-5200-05S flow meters

5200-07S-BR

£118.10

Set of two blocking rings for resealing pipework when flow meters are removed. Suitable for CDI-5200-07S flow meters

5200-07C-BR

£118.10

Set of two blocking rings for resealing pipework when flow meters are removed. Suitable for CDI-5200-07C flow meters

We are here to help