Skip to content

omni instruments | sensors and data acquisition equipment

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
Products
Edit Content
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
Edit Content
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket
Home / Pace Scientific 4 and 8 Channel Data Logger Range / Input Scaling Modules for XR440/XR450 Data Logger
Input Scaling Modules for XR440/XR450 Data Logger

Input Scaling Modules for XR440/XR450 Data Logger

Input scaling modules for use with the XR440 and XR450 data loggers from Pace Scientific. The modules are factory calibrated to allow the XR440, or XR450, pocket logger to accept a wide range of different voltage and mA current input signals. Each individual input channel can be configured for the following:- -5 to +5vDC, 0-10vDC, 0-20vDC, 0-30vDC, 0-60vDC, 4-20mA (also 0-20mA) or the standard 0-5vDC suitable for all Pace Scientific sensor inputs. Modules plug directly into the connector block on the XR440 and will add 0.36″ to the logger length.

View Options

Need help finding the right product?

CONTACT US
  • Description

Description

Features

  • Replaces existing detachable XR440/XR450 terminal block to allow additional input ranges
  • Five DC voltages, 4-20mA and Standard inputs can be configured on any input channel.
  • Standard inputs allows all PACE sensors, probes and 0-5V inputs
  • Start/stop logging trigger available when channel one configured for standard input.

Specifications

 INPUT PART NUMBER
 -5 to +5 vDC 5V
 0-10 vDC 10V
 0-20 vDC 20V
 0-30 vDC 30V
 0-60 vDC 60V
 4-20 mA (also 0-20 mA) 20M
 ‘Standard’ input (for all PACE sensors and 0-5vDC) S

 

Module scaling is fixed at the factory and must be specified when ordering. Channels specified as ‘-S’ are ‘Standard’ channels and will accept all PACE sensors, probes and 0-5vdc signals. You must specify Channel 1 as -S (standard input) in order to use the external Start/Stop Trigger feature that is available on the XR440 Data Logger.The attached module adds 0.36″ to the Pocket Logger’s overall length. Overall width and height are unchanged.

Note: Detaching the Input Scaling Module restores the Pocket Logger to its ‘Standard’ input configuration.

4-20mA: Any Pocket Logger standard input can be converted to a 4-20mA input by connecting a 249 ohm resistor to the XR440’s, or XR450’s terminal block. (A connection diagram is provided in the Pocket Logger Software online manual). When you specify an Input Scaling Module with one or more 20mA channels, a precision (0.1% tolerance) 249 ohm resistor is built into the Scaling Module for each 20mA channel specified.

Input Impedance: All vDC ranges: 100k ohms.

Size: 1.6″ wide x 0.75″ deep x 0.55″ high (41mm wide x 19mm deep x 14mm high)

An Input Scaling Module is not required for Pace Sensors, 0-5vDC signals, 2-wire resistance signals and potentiometers. All of which can be directly connected to the XR440/xr450 inputs and selected from the internal settings menu in the software.

Product

Ref

Price

Product Description

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2025 | Design. Build. Host.

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

Call us on +44 (0)1382 443000

Enquire now