Skip to content

omni instruments | sensors and data acquisition equipment

Omni Instruments Ltd

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
Omni Instruments Ltd
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Products
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket

PR5104A Repeater/Power Supply

Home / Our Brands / PR Electronics / Signal Isolation / PR5104A Repeater/Power Supply

PR5104A Repeater/Power Supply

The PR5104A provides transmitter power, signal isolation and analogue signal conversion in a DIN rail module. It interfaces compatible two-wire transmitters or current and voltage signals with PLCs, controllers, displays and data-acquisition equipment.

Available in one- or two-channel versions, it provides galvanic separation between input, output and supply circuits. This helps prevent ground-loop currents from affecting measurements where connected equipment operates at different earth potentials.

Transmitter Supply and Signal Conversion

The integrated loop supply powers compatible two-wire transmitters, providing at least 17.1 V at 20 mA. The available voltage must accommodate the transmitter’s requirements and voltage drops elsewhere in the loop.

For externally powered signals, the 5104A operates as an isolator or converter. It can repeat a supported current or voltage range, or convert between the two signal types to match the receiving equipment. Depending on configuration, the output can operate as an active current or voltage source, or as a two-wire transmitter output.

DIP-Switch Range Selection

Internal DIP switches select from 20 factory-calibrated measurement ranges without requiring recalibration. This allows the module to be configured for common analogue interfaces without programming software or a separate display.

A response time of less than 25 ms supports applications requiring prompt transmission of changing process measurements.

DIN Rail Installation and Universal Power

The 23.5 mm-wide housing mounts vertically or horizontally on standard 35 mm DIN rail. The two-channel version accommodates two separate signals within the same housing, reducing the space required per channel.

A universal supply input accepts 21.6-253 vAC or 19.2-300 vDC, providing flexibility when integrating the module into existing control panels.

Options

Type Input Output Channels
5104A A: 0-20mA
B: 4-20mA
E: 0-10V
F: 2-10V
1: 0-20mA
2: 4-20mA
4: 0-1V
5: 0.2-1V
6: 0-10V
7: 2-10V
A: Single
B: Double
 

Applications

Providing stable, isolated power to loop-powered sensors in industrial automation loops.
Saving space in switchboards by utilising the dual-channel version to manage up to 84 channels per metre of DIN rail.
Electrically separate field instruments from PLCs, displays or data-acquisition equipment to help prevent measurement errors caused by earth-potential differences.
Match a transmitter’s current output to a compatible voltage input on receiving equipment using the supported range settings.
Convert a supported voltage signal into a current signal for connection to compatible process-control inputs.
Interface two separate measurement signals in one housing where control-panel space is limited.

Frequently Asked Questions

▶ Q: What does the PR 5104A do?
A: The PR 5104A powers compatible two-wire transmitters and provides galvanic isolation for analogue current or voltage signals. It can repeat a signal in the same format or convert it between supported current and voltage ranges.
▶ Q: Can it power a two-wire 4–20 mA transmitter?
A: Yes. Its transmitter supply provides at least 17.1 V at 20 mA. Check that this is sufficient for the transmitter and the voltage drop across the connected wiring and other loop components.
▶ Q: Is it available with two channels?
A: Yes. One- and two-channel versions are available. The two-channel version handles two separate analogue signals within a single DIN rail housing.
▶ Q: How are the input and output ranges configured?
A: Internal DIP switches select from 20 factory-calibrated measurement ranges. These standard ranges can be selected without recalibration.
▶ Q: Why use galvanic isolation?
A: Isolation separates the input, output and power-supply circuits electrically. This helps prevent ground-loop currents from affecting measurements when field instruments and control equipment operate at different earth potentials.
▶ Q: What power supply does it require?
A: The PR 5104A accepts a universal supply of 21.6-253 vAC or 19.2-300 vDC. This powers the module and its transmitter-supply function.

5104AA

5104AA

PR 5104AA Programmable Repeater/Power Supply with Universal AC or DC Power Supply. Dip Switch Configurable Input: 0-20mA, 4-20mA, 0-10V or 2-10V, Output: 0-20mA, 4-20mA, 0-1V, 0.2-1V, 0-10V or 2-10V. 3.75kVAC isolation voltage. Power supply 21.6 - 253vAC or 19.2 - 300vDC. DIN Rail mounted. Dimensions: 109 x 23.5 x 130mm. Operating Temperature -20 to +60°C, 0-95%RH (non-condensing).

£284.00
Add to Basket More Info
5104AB

5104AB

PR 5104AB Programmable Repeater/Power Supply with Universal AC or DC Power Supply. Dip Switch Configurable Input: 0-20mA, 4-20mA, 0-10V or 2-10V, Output: 0-20mA, 4-20mA, 0-1V, 0.2-1V, 0-10V or 2-10V. 3.75kVAC isolation voltage. Power supply 21.6 – 253vAC or 19.2 – 300vDC. DIN Rail mounted. Dimensions: 109 x 23.5 x 130mm. Operating Temperature -20 to +60°C, 0-95%RH (non-condensing).

£400.00
Add to Basket More Info

CONTACT US

8:30am to 5pm Monday to Thursday
8:30am to 3pm on Friday.

  • +44 (0) 1382 443000
  • info@omni.uk.com

A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.

Technical Sales

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2026 | Design. Build. Host.

        We are here to help

        Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

        Call us on +44 (0)1382 443000