Skip to content

omni instruments | sensors and data acquisition equipment

Omni Instruments Ltd

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
Omni Instruments Ltd
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Products
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket

PR5715 Panel Displays

Home / Our Brands / PR Electronics / Panel Displays / PR5715 Programmable LED Indicator

PR5715 Programmable LED Indicator

Process Display with Four Relay Outputs

The PR 5715 programmable panel indicator combines local measurement display with four potential-free changeover relays for alarm switching and control. Its configurable input accepts current, voltage, RTD, thermocouple, linear resistance and potentiometer signals.

The four-digit LED display provides readings from −1999 to 9999, with a programmable decimal point. Scaling allows the displayed value to represent the measured process variable.

Multiple Alarm and Control Limits

Four relay outputs allow separate thresholds to be assigned to the same measured input. This supports staged switching or multiple alarm levels within a suitable control arrangement.

During commissioning, each relay can be activated or deactivated independently of the input signal, helping engineers check connected circuits.

The PR 5715D also provides an analogue current output for retransmitting the measurement to a PLC, controller or data logger.

Custom Linearisation and PC Configuration

Standard settings are accessible through the front buttons, with scrolling help text in eight languages. PC configuration using PReset software and a compatible programming interface provides additional functions, including custom linearisation and special input signals.

Custom linearisation is useful where the relationship between the input and required display value is non-linear. For example, a suitable tank level signal can be converted into volume using the tank’s known characteristics.

Panel Mounting and Universal Supply

The PR5715 fits a 44.5 × 91.5 mm panel cutout. Correct installation with the supplied gasket provides IP65 protection at the front.

The universal supply accepts 21.6–253 VAC or 19.2–300 VDC. Galvanic isolation separates the input, outputs and supply.

Options

TypeVersion
5715B: Display and 4 relays
D: Display, analogue current output and 4 relays

 

Applications

Use custom linearisation to convert a suitable level signal into volume for tanks with a non-linear level-to-volume relationship.
Use up to four relay outputs for separate process limits or staged switching.
Display measurements from supported RTDs or thermocouples.
Scale compatible current, voltage, resistance or potentiometer signals into a local readout.
Use an analogue-output version to send the measured value to a controller or logger.

Frequently Asked Questions

â–¶ Q: Can the PR 5715 power a 2-wire transmitter directly?
A: Yes, the 5715 features an integrated auxiliary supply providing 16–25 VDC (up to 20 mA), allowing it to power external sensors or transmitters without an additional power supply.
â–¶ Q: How do I configure the 5715 for a specific sensor type?
A: The unit is fully programmable via the front keys using a menu-guided scrolling text, or via PC software for more complex setups.
â–¶ Q: What is the difference between the 5715B and 5715D models?
A: Both models include 4 relay outputs, but the 5715D also includes an isolated 0/4...20 mA analogue output for signal retransmission.
â–¶ Q: Can I use the 5715 in high-washdown or wet environments?
A: The front panel is rated IP65 as standard, but it can be upgraded to IP67 protection by using the optional 8335 splash-proof cover.
â–¶ Q: Does the unit support multi-point linearisation?
A: Yes, the 5715 supports linearisation and specialized functions like square root for flow applications, configurable through the setup menu.

5715B

5715B

PR 5715B 4 Digit Red LED display. Accepts a single 4-20mA, 0-1V, 0.2.1V, 0-10V, PT100 and Thermocouple inputs. Programmable via front keys, 2.3kVAC Galvanic isolation, 4 x Relay output. Universal power supply: 21.6 to 253vAC or 19.2 to 300vDC, plus Auxiliary supply for sensors of 16-25vDC / 0-20mA. IP65 Rated with dimensions of 48 x 96 x 120mm, requires a Cutout 44.5 x 91.5mm.

£295.00
Add to Basket More Info
5715D

5715D

PR 5715D 4 Digit Red LED display. Accepts a single 4-20mA, 0-1V, 0.2.1V, 0-10V, PT100 and Thermocouple inputs. Programmable via front keys, 2.3kVAC Galvanic isolation, 4 x Relay and Analogue 4-20mA output. Universal power supply: 21.6 to 253vAC or 19.2 to 300vDC, plus Auxiliary supply for sensors of 16-25vDC / 0-20mA. IP65 Rated with dimensions of 48 x 96 x 120mm, requires a Cutout 44.5 x 91.5mm.

£360.00
Add to Basket More Info
8335

8335

Splash-proof cover for PR displays, IP67.

£32.00
Add to Basket More Info

CONTACT US

8:30am to 5pm Monday to Thursday
8:30am to 3pm on Friday.

  • +44 (0) 1382 443000
  • info@omni.uk.com

A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.

Technical Sales

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2026 | Design. Build. Host.

        We are here to help

        Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

        Call us on +44 (0)1382 443000