Description
The TxIsoPack is an isolated 2-wire 4-20mA head mounted temperature transmitter that stands out for its unique, user-friendly configuration method. It’s a loop-powered, 2-wire device designed for signal conversion from a wide range of industrial sensors into a standard 4-20mA output. Its core strengths lie in its universal input capabilities and the simplicity of its setup. Each head mounted transmitter has a USB port to allow connection to a PC or mobile for configuration.
Features
- Universal Input: The TxIsoPack can accept a comprehensive list of sensor inputs, standard thermocouples (Types J, K, T, E, N, R, S, B), PT100 and low-level mV signals (0-50mV). This single-device versatility allows it to replace multiple dedicated transmitters.
- Integrated USB Port: The most significant feature is the built-in micro-USB port. This eliminates the need for a separate, proprietary configuration interface. Users can simply connect the transmitter directly to a PC or even a smartphone (with an OTG adapter) for quick and easy programming, calibration, and monitoring. The device can even be powered by the USB connection during setup.
- Measurement Accuracy: It delivers high precision with typical accuracy of 0.3% for thermocouples, and 0.2% for PT100’s and mV signals, ensuring reliable readings for critical process control.
- Cold Junction Compensation: Thermocouple sensors allow for cold junction compensation to improve accuracy.
- Durable & Compact Design: Designed for DIN form B sensor head mounting, its compact size and robust housing (ABS UL94-HB) make it suitable for installation in tight spaces while ensuring durability and resistance to industrial environments.
Specifications
| Sensor Input | Sensor Type | Measurement Range | Minimum Measurement Range |
| Thermocouple K | -150 to 1,370°C (-238 to 2498F) | 100°C | |
| Thermocouple J | -100 to 760°C (-148 to 1400F) | 100°C | |
| Thermocouple R | -50 to 1,760°C (-58 to 3200F) | 400°C | |
| Thermocouple S | -50 to 1,760°C (-58 to 3200F) | 400°C | |
| Thermocouple T | -160 to 400°C (-256 to 752F) | 100°C | |
| Thermocouple N | -270 to 1,300°C (-454 to 2375F) | 100°C | |
| Thermocouple E | -90 to 720°C (-130 to 1328F) | 100°C | |
| Thermocouple B | 500 to 1,820°C (932 to 3308F) | 400°C | |
| PT100 (2-, 3- and 4-wire) | -200 to 650°C (-328 to 1202F) | 40°C | |
| MilliVolt | 0 to 50mV | 5mV | |
| Temperature Unit | °C or °F, software selectable | ||
| Accuracy | Sensor Type | Typical | |
| PT100 | 0.2% of span | ||
| Thermocouple Type K, J, T, E, N, R, S, B | 0.7% of span | ||
| MV | 0.2% of span | ||
| Measurement Compensation | Thermocouple: Cold junction compensation PT100: For 2-Wire, pins 3 and 4 should be connected. |
||
| Output | Output Signal: Linearised 4-20 or 20-4mA current, 2 wire Resolution: 4µA |
||
| Temperature Effect | ±0.16% / 25°C (77 °F) | ||
| Response Time | Less than 500ms (typical) | ||
| Power Supply | 12 to 35vDC | ||
| Operating Conditions | Temperature: -20 to 75°C (-4 to +167 F) Humidity: 0 to 90 %RH |
||
| Approvals / Standards | CE NAMUR NE43 compliant RoHS compliant Reach |
||
| Protection | Internal protection against reverse polarity | ||
| Isolation | No electrical isolation between input and output | ||
| Dimensions | 44mm (diameter) x 24mm (height) (1.73 inches (diameter) x 0.94 inches (height)) | ||
| Wire Cross Section | 0.14 to 1.5mm² (26 AWG to 15 AWG) | ||
| Housing Material | ABS UL94-HB (standard impact strength, flaming resistance and antistatic) | ||
| Mounting | DIN form B sensor head | ||
| Interface Communication | USB mini-B type, with silicon cover protection | ||
| Configuration | TxConfig | ||