MSR175 Shock Transportation Data Logger
Kenny Laidlaw
Oct 01,2018
The MSR175 shock transportation data logger is the newest miniature logger from MSR.  The MSR175 ut...read more >
XR5 High Performance Data Logger

XR5 High Performance Data Logger

Quick Overview

The XR5 data logger is a compact logger with 8 analogue and 3 digital channels. Logging rates are programmable from 1Hz to 24 hours, with a fast mode logging up to 1000Hz. Logging modes include manual start, external trigger and log on alarm. The resolution is 12 bit and battery life is up to 2 years. Programming and data retrieval is simple via free Windows LogXR software.
View Options

Details

  • XR5-SE   8 channel, 0-2.5v, 0-5v, mV, 4-20mA, 30K thermistor, contact closure + 3 digital I/O
  • with 64K or  256K memory
  • Optional mV ranges 0-20mV to 0-1000mV
  • Small, light weight
  • Low power consumption, battery or external power
  • GSM modem support.

Use our online calculator to work out input signal ranges and scaling in engineering units for data loggers. Also calculates shunt resistor values, resolution and null point offsets.

Specifications

Both models have eight analog inputs and three pulse inputs.
Each analog input (channels 1-8) is user selectable for any of the following:


Temperature (A.rvt): YSI 10k Thermistor ‘H mix’ or equivalent.
Temperature (B.rvt): YSI 10k Thermistor ‘B mix’ or equivalent.
Temperature PT9xx: Pace PT900 series Temperature Probe.
Temperature PT510: Pace PT510 or PT520 Platinum RTD (10k ohm element)
Light Sensor LS100: Pace LS100 Light Sensor
Switch or Contact: Non-powered contact closure or dc voltage (5v max).
Resistance: 2-wire resistance (midpoint = 30k ohms, best resolution is from 1k to 300k ohms).
0-2.5v: 0 to 2.5v input, >10Mohm input impedance.
0-5v: 0 to 5v input, >10Mohm input impedance. (suitable for most Pace sensors for Pressure, Current or Voltage.
TRH-160 Probe: TRH-160 Temperature/Humidity Probe
TRH-100 Probe: TRH-100 Temperature/Humidity Probe
4-20mA signals: Use the 0-2.5v input selection with a 124 Ohm shunt resistor.  When monitoring multiple 4-20mA signals, all shunt resistors connect to a shared common and all 4-20mA transducers should be powered by a single power supply (typically 24vDC).

Additionally, the XR5-SE may be factory equipped with two millivolt input channels. This provides two millivolt range selections and one internal precision temperature sensor (12th channel). All existing input ranges and capabilities of the XR5-SE are retained. The 20mV & 50mV units are best for use with thermocouples.

Miilivolt range selection table


"Full Scale" Selected 
  "Half Scale" Selected
Model Number Range Resolution Range
Resolution
XR5-SE-20mV  0-20mV  4.8μV  0-10mV  2.4μV
XR5-SE-50mV  0-50mV  12μV  0-25mV  6μV
XR5-SE-100mV  0-100mV  24μV  0-50mV  12μV
XR5-SE-250mV  0-250mV  61μV  0-125mV  30μV
XR5-SE-500mV  0-500mV 122μV  0-250mV  61μV
XR5-SE-1000mV  0-1000mV 244μV  0-500mV 122μV

Availability: In stock

Price range : £608.95 - £815.19

Price as configured: £608.95

* Required Fields

Price as configured: £608.95

 

Part Builder

Description       XR5 Data Logger. 8 channels with standard input ranges of 0-5v and 0-2.5v and 2.5v & 5v channel excitation. Also 3 digital I/O, configurable as 3 pulse external trigger or alarm output
 

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
Data Loggers
XR5-SE
XR5-SE
XR5 8 channel logger. 8 chan Input range 0 - 2.5 volts or 5 V, resistance/temperature/2.5v I/P. With 2.5v & 5v channel excitation and SMS text messaging. Memory 64K. Also 3 digital I/O, configurable as 3 pulse external trigger or alarm O/P
View FileData Sheet
   Size: (86.96 KB)
View FileXR5-SE Manual
   Size: (1.14 MB)
£584.57
or call us for a quote
XR5-SE-M
XR5-SE-M
XR5 8 channel logger. 8 chan Input range 0 - 2.5 volts or 5 V, resistance/temperature/2.5v I/P. With 2.5v & 5v channel excitation and SMS text messaging. Memory 256K. Also 3 digital I/O, configurable as 3 pulse external trigger or alarm O/P
£608.98
or call us for a quote
 
XR440 Multiplexer & Communication Cable
IC-209
Connects Pocket Logger, or M31 Multiplexer, to 9-pin Com port of a PC. Allows for configuration of and downloading data from XR440 via Pocket Logger Software. Cable length 5 feet.
£32.23
or call us for a quote
USB-A
USB-A
RS232 Serial to USB interface converter. Cable length 10cm. Can be used to convert the HPS-120 serial output port to a USB port output. The USB-A may also be used for Pace data loggers and with various other devices to convert from RS232 to USB.
£34.50
or call us for a quote
 
Replacement Lithium Batteries
BATT-0004
BATT-0004
3.6V Lithium AA Battery. Supplied batteries may differ from the picture.
£7.78
or call us for a quote