UVS Series Ultraviolet Radiometers.

UVS Series Ultraviolet Radiometers.

Quick Overview

The UVS series of UV Radiometers provide outputs for specific types of Ultraviolet radiation. Units have a spectral response that is adapted to UVA, UVB and the UVE Erythemal (sunburn) action spectrum of the human skin, units are available to provide UVA, UVB and UVE measurements, or combinations of UVA/B and UVA/E radiation. The UVS instruments are fully weather protected and suitable for use in all environments. All UVS instruments are supplied with calibration data files that include the spectral response function of the individual instruments.
View Options

Details

The Ultraviolet spectrum covers wavelength ranges 100-280nm (UVC), 280-315nm (UVB) and 315-400nm (UVA). Almost all UVC, and approximately 90% of UVB from the Sun is absorbed by the Earth’s atmosphere. The Ozone layer absorbs the majority, whilst the amount of atmosphere the radiation has to penetrate reduces the rest. Therefore. the spectral distribution of atmospheric UV irradiance is very variable, depending upon the atmospheric conditions. During the calibration of the UVS radiometers this variability is taken into account by systematic convolution of the spectral response function with observed and modelled atmospheric UV spectra. Due to this sophisticated calibration method a leading degree of measurement accuracy is achieved.

The UV radiation that makes it through the ozone layer can cause the following problems, particularly for materials and people that spend extended periods of time outdoors:

  • Weaken plastics – Many polymers used in consumer items (including plastics, nylon and polystyrene) are broken down or lose strength due to exposure to UV light.
  • Fades colours – Many pigments (used for colouring food, cosmetics, fabric,plastic, paint, ink and other materials) and dyes absorb UV and change colour. Fabrics, furnishings and paintings need protection from UV (fluorescent lamps as well as sunlight) to prevent colour change or loss.
  • Human biology - Short-term exposure can stimulates the production of vitamin D or melanin for a suntan but prolonged exposure can cause sunburn, skin cancer, cataract, suppression of the immune system or premature aging of the skin.

The spectral responses of the UVS Radiometers are carefully adapted to provide UVA, UVB and UVE measurements, or combinations of UVA/B and UVA/E radiation. Separate measurement of UVA and UVB can be carried out under controlled conditions in environmental test chambers using artificial UV light sources for testing materials, products, or pigment development.

A specific UVE radiometer is available to measure the Erythemally active UV irradiance that is used in the development of cosmetics, sun block and creams.

All the radiometers have an analogue voltage output which is proportional to the measured UV irradiance. In addition, the UVS models have a voltage output to monitor the internally stabilised temperature.

Specification

  UVS-A-T UVS-B-T UVS-E-T
Spectral Range 315 to 400nm 280 to 315nm ISO 17166:1999
CIE S 007/E-1998
Typical Calibration Factor 30W/m²/V 2W/m²/V 0.2W/m²/V
Output Range 0 to 90W/m² 0 to 6W/m² 0 to 0.6W/m²
Non-stability (change/year) <5%
Directional error <2.5% (up to 70° zenith angle)
Temperature response Temperature stabilized internally at 25°C, ±2°C
Operating temperature range -40 to +50°C
Power Supply 7 to 18vDC @ 8W
UVIATOR Software Included, corrects for solar zenith angle and Ozone column concentration

To improve the measurement accuracy of the UVS radiometers the CVF4 ventilation unit can be used. It can be used outdoors under all weather conditions and includes a built in heater to keep the air just above ambient temperature which helps disperse precipitation and melt frost, or even melt snow and ice in cold climates. The CVF4 has a tacho output that can be used to check the proper operation of the CVF4. The output signal is 5V and nominal output should be at 146Hz. Higher frequency would suggest the filter needs replaced, whilst lower frequency could highlight an issue with the ventilator.

The UVS Series units are not suitable for the measurement of total global UV radiation. For measurement of these parameters we recommend the CUV Broadband UltraViolet Radiometer.

Availability: Stock Item

 

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
UVS-A-T Series Ultraviolet Radiometer
0354920-000
UVS-A-T UV Radiometer. Suitable for the measurement of atmospheric UVA irradiance. Power supply 7-18vDC @ 8W, output 0-3V for 0-90Wm² at a typical calibration factor of 30Wm²/V. Single 2mm glass dome with integrated leveling and Sun shield. Spectral range 315 - 400nm, response time less than 1.5s (95%), non-linearity 1%, directional error 2.5% (up to 70° Zenith angle), operating temperature -40 to +50°C. Supplied with no plug or cable.
View FileDatasheet
   Size: (966.52 KB)
£4,211.00
or call us for a quote
0354920-002
UVS-A-T UV Radiometer. Suitable for the measurement of atmospheric UVA irradiance. Power supply 7-18vDC @ 8W, output 0-3V for 0-90Wm² at a typical calibration factor of 30Wm²/V. Single 2mm glass dome with integrated leveling and Sun shield. Spectral range 315 - 400nm, response time less than 1.5s (95%), non-linearity 1%, directional error 2.5% (up to 70° Zenith angle), operating temperature -40 to +50°C. Supplied with waterproof 8-pin plug connector with 10m of pre-wired yellow signal cable.
£4,300.00
or call us for a quote
 
UVS-B-T Series Ultraviolet Radiometer
0354925-000
UVS-B-T UV Radiometer. Suitable for the measurement of atmospheric UVB irradiance. Power supply 7-18vDC @ 8W, output 0-3V for 0-6Wm² at a typical calibration factor of 2Wm²/V. Single 2mm glass dome with integrated levelling and Sun shield. Spectral range 280 - 315nm, response time less than 1.5s (95%), non-linearity 1%, directional error 2.5% (up to 70° Zenith angle), operating temperature -40 to +50°C. Supplied with no plug or cable.
£4,736.00
or call us for a quote
0354925-002
UVS-B-T UV Radiometer. Suitable for the measurement of atmospheric UVB irradiance. Power supply 7-18vDC @ 8W, output 0-3V for 0-6Wm² at a typical calibration factor of 2Wm²/V. Single 2mm glass dome with integrated levelling and Sun shield. Spectral range 280 - 315nm, response time less than 1.5s (95%), non-linearity 1%, directional error 2.5% (up to 70° Zenith angle), operating temperature -40 to +50°C. Supplied with waterproof 8-pin plug connector with 10m of pre-wired yellow signal cable.
£4,825.00
or call us for a quote
 
UVS-E-T Series Ultraviolet Radiometer
0354930-000
UVS-E-T UV Radiometer. Suitable for the measurement of atmospheric UVE irradiance. Power supply 7-18vDC @ 8W, output 0-3V for 0-0.6Wm² at a typical calibration factor of 0.2Wm²/V. Single 2mm glass dome with integrated levelling and Sun shield. Spectral range ISO 17166:1999 CIE S 007/E-1998, response time less than 1.5s (95%), non-linearity 1%, directional error 2.5% (up to 70° Zenith angle), operating temperature -40 to +50°C. Supplied with no plug or cable.
£4,017.00
or call us for a quote
0354930-002
UVS-E-T UV Radiometer. Suitable for the measurement of atmospheric UVE irradiance. Power supply 7-18vDC @ 8W, output 0-3V for 0-0.6Wm² at a typical calibration factor of 0.2Wm²/V. Single 2mm glass dome with integrated levelling and Sun shield. Spectral range ISO 17166:1999 CIE S 007/E-1998, response time less than 1.5s (95%), non-linearity 1%, directional error 2.5% (up to 70° Zenith angle), operating temperature -40 to +50°C. Supplied with waterproof 8-pin plug connector with 10m of pre-wired yellow signal cable.
£4,106.00
or call us for a quote
 
UVS-A-T & UBS-B-T Combined Ultraviolet Radiometer
0354950-000
UVS-A-T & UVS-B-T combined UV Radiometer. Suitable for the measurement of atmospheric UVA and UVB irradiance with separate outputs. Power supply 7-18vDC @ 8W, UVA output 0-3V for 0-90Wm² at a typical calibration factor of 30Wm²/V and UVB output 0-3V for 0-6Wm² at a typical calibration factor of 2Wm²/V. Single 2mm glass dome with integrated leveling and Sun shield. Spectral range 280 - 400nm, response time less than 1.5s (95%), non-linearity 1%, directional error 2.5% (up to 70° Zenith angle), operating temperature -40 to +50°C. Supplied with no plug or cable.
£6,106.00
or call us for a quote
0354950-002
UVS-A-T & UVS-B-T combined UV Radiometer. Suitable for the measurement of atmospheric UVA and UVB irradiance with separate outputs. Power supply 7-18vDC @ 8W, UVA output 0-3V for 0-90Wm² at a typical calibration factor of 30Wm²/V and UVB output 0-3V for 0-6Wm² at a typical calibration factor of 2Wm²/V. Single 2mm glass dome with integrated leveling and Sun shield. Spectral range 280 - 400nm, response time less than 1.5s (95%), non-linearity 1%, directional error 2.5% (up to 70° Zenith angle), operating temperature -40 to +50°C. Supplied with two waterproof 8-pin plug connector with 10m of pre-wired yellow signal cable.
£6,285.00
or call us for a quote
 
UVS-A-T & UBS-E-T Combined Ultraviolet Radiometer
0354955-000
UVS-A-T & UVS-E-T combined UV Radiometer. Suitable for the measurement of atmospheric UVA and UVE irradiance with separate outputs. Power supply 7-18vDC @ 8W, UVA output 0-3V for 0-90Wm² at a typical calibration factor of 30Wm²/V and UVE output 0-3V for 0-0.6Wm² at a typical calibration factor of 0.2Wm²/V. Single 2mm glass dome with integrated leveling and Sun shield. Spectral range 315 - 400nm, response time less than 1.5s (95%), non-linearity 1%, directional error 2.5% (up to 70° Zenith angle), operating temperature -40 to +50°C. Supplied with no plug or cable.
£5,618.00
or call us for a quote
0354955-002
UVS-A-T & UVS-E-T combined UV Radiometer. Suitable for the measurement of atmospheric UVA and UVE irradiance with separate outputs. Power supply 7-18vDC @ 8W, UVA output 0-3V for 0-90Wm² at a typical calibration factor of 30Wm²/V and UVE output 0-3V for 0-0.6Wm² at a typical calibration factor of 0.2Wm²/V. Single 2mm glass dome with integrated leveling and Sun shield. Spectral range 315 - 400nm, response time less than 1.5s (95%), non-linearity 1%, directional error 2.5% (up to 70° Zenith angle), operating temperature -40 to +50°C. Supplied with two waterproof 8-pin plug connector with 10m of pre-wired yellow signal cable.
£5,796.00
or call us for a quote
 
Connection Options for SMP's, CMP21 (PT100), CMP22 (PT100), CGR3 (PT100), CGR4 (PT100), CHP1, CNR4, UVS, CSD3
2523146
Waterproof 8-pin plug connector for the following Kipp & Zonen equipment. SMP Pyranometers, CMP Pyranometers with PT100 output, CGR3 and CGR4 with PT100 output, CHP1, CNR4, UVS Radiometers and CSD3 Sunshine Duration Sensors.
£25.00
or call us for a quote
0362621
Waterproof 8-pin plug connector with 10m of pre-wired high quality yellow signal cable with 8 wires and a shield covered with black sleeve. Suitable for: For SMP Smart Pyranometers, CMP21 (PT100), CMP22 (PT100), CGR3 (PT100), CGR4 (PT100), CHP1, CNR4, UVS, CSD3
£90.00
or call us for a quote
0362623
Waterproof 8-pin plug connector with 25m of pre-wired high quality yellow signal cable with 8 wires and a shield covered with black sleeve. For SMP Smart Pyranometers, CMP21 (PT100), CMP22 (PT100), CGR3 (PT100), CGR4 (PT100), CHP1, CNR4, UVS, CSD3
£184.00
or call us for a quote