Omni Instruments
contact icon+44 (0) 845 9000 601
+44 (0) 1382 443000
WE ARE HERE TO HELP

Contact our technical sales team now to discuss your requirements

help icon
MY BASKET basket arrow

£0.00

My Cart

You have no items in your shopping cart.

Click basket to edit.

Products

Latest added news blog
CDI5450 Hot Tap Compressed Air Flow Meter
Kenny Laidlaw
Jun 14,2017
The CDI 5450 is a hot tap compressed air flow meter is a modified version of the 5400 compressed air...read more >
GRD Solar Panel Efficiency Monitoring System

GRD Solar Panel Efficiency Monitoring System

2-3 Weeks Del.

Quick Overview

The GRD Solar Panel Efficiency Monitoring System measures solar radiation, solar power output ( Dc voltage and current or water temperature ), and current weather data such as air temperature, wind speed etc. and delivers the data wirelessly using GPRS to a secure web page.
View Options

Details

The GRD Solar Panel Efficiency Monitor provides a cost effective way to monitor solar panel performance on remote sites. It measures the electrical outputs from PV panels, or water temperature from solar collectors, along with incoming solar radiation, and air temperature. It can be integrated with your existing metering, or supplied as a complete system with voltage and current sensors and a full range of environmental sensors for solar radiation and weather.

  • Stand alone system with integral GPRS/GSM modem
  • Automatically emails hourly, daily or weekly reports
  • Publishes data direct to a web page
  • Web interface SMS text messages and / or emails on alarm
  • Remote configuration via browser interface
  • 6 Analogue inputs
  • 14 Digital State Inputs
  • 2 Counter Inputs
  • 2 Relay Outputs (5A at 24vDC)
  • Expand to 32 additional analogue/digital channels

Availability: Stock Item

 

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
GRD3000 Series GPRS Data Logger
GRD3002-XF-PL-MB
GRD3002-XF-PL-MB
GRD3002-XF-PL-MB GSM/GPRS data logger with 6 analogue inputs (0-10v or 4-20mA), 2 pulse inputs, 14 digital state input and 6 open collector digital outputs. RS232/485 serial port MODBUS master (reads up to 32 registers). Power supply 10-30vDC. The GRD will connect to a remote server to generate a MySQL database for data logging. Our M2M web interface can also be used for monitoring and to provide SMS or e-mail alarming. GRD unit has an internal back-up memory for up to 100,000 readings in the event of connection issues with mobile network or remote server.
View FileData Sheet
   Size: (n/a)
£825.86
or call us for a quote
 
GRD3300 Series GPRS Data Logger
GRD3301-XF
GRD3301-XF
GRD3301-XF GSM/GPRS data logger and SMS alarm unit with 2 Analogue Inputs (Ch1 configured to 0-1V, 0-10V or 4-20mA; Ch2 configured to PT100, 0-10V or 4-20mA), 4 digital state/counter inputs (2 configurable as NPN Outputs). Power supply 9-30vDC. USB port for local programming and configuration. The GRD will connect to a remote server to generate a MySQL database for data logging. Our M2M web interface can also be used for monitoring and to provide SMS or e-mail alarming. GRD unit has an internal back-up memory for up to 100,000 readings in the event of connection issues with mobile network or remote server. Units can also be configured to send direct SMS messages on alarm conditions on any analogue or digital state input and accept SMS instructions to activate a digital output.
View FileData Sheet
   Size: (263.5 KB)
£431.98
or call us for a quote
GRD3305-XF
GRD3305-XF
GRD3305-XF GSM/GPRS data logger and SMS alarm unit with 4 analogue inputs (0-1v, 0-10v, 4-20mA), 4 digital state/counter inputs (2 configurable as NPN Outputs). RS232/485 serial port MODBUS master (reads up to 100 registers). Power supply 9-30vDC. USB port for local programming and configuration. The GRD will connect to a remote server to generate a MySQL database for data logging. Our M2M web interface can also be used for monitoring and to provide SMS or e-mail alarming. GRD unit has an internal back-up memory for up to 100,000 readings in the event of connection issues with mobile network or remote server. Units can also be configured to send direct SMS messages on alarm conditions on any analogue or digital state input and accept SMS instructions to activate a digital output.
View FileData Sheet
   Size: (629.94 KB)
£669.54
or call us for a quote
GRD3534-XF
GRD3534-XF
GSM/GPRS data logger with 8 analogue inputs, 0-1v, 0-10v, 4-20mA, 16 digital inputs or state (8 configurable as counters up to 1kHz or NPN outputs). 2 x RS232/485 serial port MODBUS master (reads up to 100 registers). Power supply 9-30vDC. Data sent to web interface or MySQL database as preferred by client. USB serial interface. Memory 50,000 readings.
£904.89
or call us for a quote
 
GRD1300XF GPRS Data Logger
GRD1300-XF
GRD1300-XF
GRD1300-XF GSM/GPRS data logger and SMS alarm unit with an RS232/485 serial port MODBUS master (reads up to 100 registers). Power supply 9-30vDC. USB port for local programming and configuration. The GRD will connect to a remote server to generate a MySQL database for data logging. Our M2M web interface can also be used for monitoring and to provide SMS or e-mail alarming. GRD unit has an internal back-up memory for up to 100,000 readings in the event of connection issues with mobile network or remote server. Units can also be configured to send direct SMS messages on alarm conditions on any input and accept SMS instructions to activate a digital output.
£529.16
or call us for a quote
SP-LITE-EX SENS
SP-LITE-EX SENS
SP-LITE Pyranometer is suitable for solar irradiance measurements in spectral ranges of 400 to 1100nm up to a maximum of 2,000 W/m² with response time less than 1 seconds and typical sensitivity of 60 to 100µV/W/m² that varies less than 0.15%/°C from -30 to +70°C. The pyranometer uses a Double 2mm glass domes to protect the thermopile from external influences. SP-LITEs are fitted with 5m of cable for direct connection to a data logger.
View FileDatasheet
   Size: (524.7 KB)
£326.00
or call us for a quote
CMP3
CMP3
CMP 3 Pyranometer, ISO Second Class, is suitable for solar irradiance measurements in spectral ranges of 310 to 2800nm up to a maximum of 2,000 W/m² with response time <18 seconds and typical sensitivity 10µV/W/m² that varies less than 5 % from -10 to +40°C. The pyranometer uses a 4mm dome to protect the thermopile from external influences. CMP3s are fitted with 10m of cable for connection to amplifier, data loggers and other instrumentation.
View FileDatasheet
   Size: (487.19 KB)
£561.00
or call us for a quote
OMNI-C1-10V
Omni C Series Current Transducer. Selectable current ranges: 0-10, 0-20 or 0-50A with a 0-10V output, accuracy 1%FS. Suitable for single phase circuits with a frequency 40-400Hz. Isolation voltage 2000V. Split core transducer with a 20 x 22mm conducer hole. Certification: CE, UL and RoHS.
View FileDatasheet
   Size: (136.02 KB)
£102.58
or call us for a quote
OMNI-C2-10V
Omni C Series Current Transducer. Selectable current ranges: 0-100, 0-150 or 0-200A with a 0-10V output, accuracy 1%FS. Suitable for single phase circuits with a frequency 40-400Hz. Isolation voltage 2000V. Split core transducer with a 20 x 22mm conducer hole. Certification: CE, UL and RoHS.
£79.00
or call us for a quote
CMP11
CMP11
CMP 11 Pyranometer, ISO Secondary Standard, is suitable for solar irradiance measurements in spectral ranges of 310 to 2800 nm up to a maximum of 4,000 W/m with response time less than 5 seconds and typical sensitivity of 7 to 14µV/W/m that varies less than 1 % from -10 to +40°C. The pyranometer uses a Double 2 mm glass domes to protect the thermopile from external influences. CMP11s are fitted with 10m of cable for connection to a TxRail or DigiRail-2A module to GRD Solar Efficiency Monitor.
£1,974.33
or call us for a quote
E13050
PT100 Class B 3-wire temperature probe to monitor solar panels temperatures. Probes are fitted with 1m flying lead and a 6mm surface mount leaf for mounted to solar panel surfaces. This sensor is ideal monitoring surface temperatures for temperature co-efficiency adjustments in solar panel power generation.
View FileDrawing
   Size: (178.63 KB)
£37.50
or call us for a quote
HBS/1/1832/CLASSA/5M
PT1000 Temperature Probe to monitor solar panels temperatures. Probes are fitted with 5m PVC flying lead and an aluminium leaf (24mm x 10mm) for mounted to solar panel surfaces. Temperature readings can be used for temperature coefficiency adjustments in solar panel power generation.
£77.44
or call us for a quote
HBS/1/2896
PT1000 Air Temperature Probe with Aluminium housing. Temperature range -40 to +80 C.
£113.49
or call us for a quote
 
HygroClip 2 Probes
HC2A-S
HC2A-S
Standard Hygroclip2 Temperature and Relative Humidity Probe. Ranges Temperature -50 to +100°C (-40 to +60°C, 0-1V outputs), Relative Humidity 0 to 100%. Accuracy +/-0.8% RH, +/-0.1°K. Comes with a black Polycarbonate housing and a Polyethylene (40µm) filter. Replaced the HC2-S probe.
£227.00
or call us for a quote
 
Stevenson Screen
SCREEN-MODEL-306
SCREEN-MODEL-306
Stevenson screen to protect the air temperature probe from the affects of rain and wind on the temperature reading. The white UV stabilized thermoplastic discs offer a high reflectivity, low thermal conductivity and rugged weather resistance. Stainless Steel mounting bracket suitable for pipes up to 27mm, or direct connection to a flat surface. Dimensions: 85mm diameter and 80mm high.
£74.83
or call us for a quote
 
Enclosure Mounted Amplifier
5331A3B-ENCL
5331A3B programmable transmitter with a 7.2-35vDC power supply. Single channel unit for PT100, thermocouple, Resistance or bi-polar mV input, producing a 2-wire 4-20mA output. 1.5kvAC galvanic isolation. Programmed to suit the connected sensor. Transmitter fitted in weatherproof enclosure with 2 cable glands.
View FileDatasheet
   Size: (245.66 KB)
£254.19
or call us for a quote
 
Yacht Anemometers
95.0146
95.0146
Meteo anemometer self-powered rotating cup anemometer for wind speed. Air velocity range 2.5 - 210Km/h , accuracy ±0.3m/s, ±5% of reading, output 0-2.1vDC (1V = 100Km/h). This product does not include an indicator.
View FileDatasheet
   Size: (148.66 KB)
£363.57
or call us for a quote
DER-10A-60mV
DER Type, Standard DIN DC Current Shunt. Range 10A Current Range with a proportional 0-60mV Output.
View FileDatasheet
   Size: (248.83 KB)
£13.10
or call us for a quote
DER-20A-60mV
DER Type, Standard DIN DC Current Shunt. Range 20A Current Range with a proportional 0-60mV Output.
£13.10
or call us for a quote
TM2UA76
TM2UA76
TM2U AC voltage transducer, single phase input range 0-250vAC, self supplied, output 0-5vDC. Accuracy 0.5% (20-120% of range), operating temperature -10 to 55°C.
View FileDatasheet
   Size: (328.98 KB)
£60.13
or call us for a quote
TM2UAA6
TM2UAA6
TM2U AC voltage transducer, single phase input range 0-440vAC, self supplied, output 0-5vDC. Accuracy 0.5% (20-120% of range), operating temperature -10 to 55°C.
£60.13
or call us for a quote
FCS521-SP-10V
FCS521-SP-10V
Omni C Series Current Transducer. Selectable current ranges: 0-10, 0-20 or 0-50A with a 0-10V output, accuracy 1%FS. Suitable for single phase circuits with a frequency 40-400Hz. Isolation voltage 2000V. Split core transducer with a 20 x 22mm conductor hole. Certification: CE, UL and RoHS.
£102.58
or call us for a quote
FCS2151-SP-10V
FCS2151-SP-10V
Omni C Series Current Transducer. Selectable current ranges: 0-100, 0-150 or 0-200A with a 0-10V output, accuracy 1%FS. Suitable for single phase circuits with a frequency 40-400Hz. Isolation voltage 2000V. Split core transducer with a 20 x 22mm conducer hole. Certification: CE, UL and RoHS.
£102.58
or call us for a quote
PRO1D-MID
PRO1D-MID
MID Certified PRO1D Energy Meter. 18mm wide DIN Rail mounting, LCD display, suitable for single phase networks measuring voltage 230vAC 50Hz, current range 0-45 amps, comes with a pulse output. MID approved suitable for billing purposes accuracy class B (EN50470.03). Suitable for measuring the kWh generated by the solar panels in single phase systems at 400V and a maximum current of 45 Amps. Meters are self powered and connect directly to the generated power. Meters generate pulse output for direct connection to GRD Solar Efficiency Monitor.
View FileDatasheet
   Size: (289.11 KB)
£32.80
or call us for a quote
RI-D19-80C
RI-D19-80C
RI-D19 Energy Meter. Suitable for measuring the kWh generated by the solar panels in single phase systems at 230V and a maximum current of 80 Amps. Meters are self powered and connect directly to the generated power. Meters provide an RS485 Modbus output for direct connection to GRD Solar Efficiency Monitor.
View FileDatasheet
   Size: (390.53 KB)
£31.50
or call us for a quote
CE4DMID001
CE4DMID001
MID Certified Conto-D4-Pt Energy Meter. Suitable for measuring the kWh generated by the solar panels in three phase systems in either 230V or 400V ranges. Meters use 5A CT Clamps for current measurement of each phase and generate pulse and RS485 Modbus outputs. Power Supply 230V. Suitable for submetering applications or solar panel efficiency monitoring.
View FileDatasheet
   Size: (535.08 KB)
£183.47
or call us for a quote
 
Curent Clamps
DBP23100/5A
DBP23100/5A
DBP23 Series split core current transformer. Primary current range 100A AC, secondary current range 5A. Dimensions 109 x 89 x 40mm with a 20 x 30mm window.
£19.23
or call us for a quote
TAS227100/5A
TAS227100/5A
TAS227 Series fixed core current transformer. Primary current range 100A AC, secondary current range 5A. Dimensions 185 x 84 x 45mm with three 27mm diameter apertures.
£19.22
or call us for a quote
 
DigiRail Modules
8811100000
8811100000
DigiRail-2A, Dual Universal Analogue Input. The unit provides a dual channel input for Thermocouples, PT100, mV, V and mA inputs with a RS485 ModBus output. The units provide a internal CJC for thermocouples and both input channels and the RS485 port are fully isolated up to 1,000V. Units are DIN Rail mountable with a working temperature of 0 to 70°C and supplied with the DigiConfig software to allow configuration.
View FileData Sheet
   Size: (169.15 KB)
£70.97
or call us for a quote
8811400100
8811400100
DigiRail-4C Module, suitable for converting 4 Counter/Digital Input to RS485 Modbus. The unit provides a four channel input for Digital Inputs, suitable for pulse or digital state inputs, with a RS485 ModBus output. The units four input channels and the RS485 port are fully isolated up to 1,000V. Units are DIN Rail mountable with a working temperature of 0 to 70°C and supplied with the DigiConfig software to allow configuration. Can be used with various GRD, ERD and CMC units to expand the standard channels.
View FileData Sheet
   Size: (169.15 KB)
£67.75
or call us for a quote
8811200100
DigiRail-2R Module, suitable for dual relay outputs via RS485 Modbus networks. Units are DIN Rail mountable with a working temperature of 0 to 70°C and supplied with the DigiConfig software to allow configuration. Can be used with various GRD, ERD and CMC units to expand the standard channels.
View File2R Manual
   Size: (129.92 KB)
£66.45
or call us for a quote