Omni Instruments
contact icon+44 (0) 1382 443000
+44 (0) 845 9000 601
WE ARE HERE TO HELP

Contact our technical sales team now to discuss your requirements

help icon
MY BASKET basket arrow

£0.00

My Cart

You have no items in your shopping cart.

Click basket to edit.

Products

Latest added news blog
MSR175 Shock Transportation Data Logger
Kenny Laidlaw
Oct 01,2018
The MSR175 shock transportation data logger is the newest miniature logger from MSR.  The MSR175 ut...read more >
TG-4080 Tinytag Transit 2 Data Logger
  • TG-4080 Tinytag Transit 2 Data Logger

TG-4080

Quick Overview

Tinytag Transit 2 (TG-4080) Temperature Logger in a bright yellow case. Temperature range -40 to +70°C. Memory 8,000 readings with delayed and magnetic switch trigger start options, plus 2 programmable alarms. Logging intervals 1 sec to 10 days with min, max & actual readings. Data can be downloaded via the USB cable, or the ACS-3030 inductive pad.
View Options

Details

The TG-4080 has been specifically designed for monitoring the temperature of products during shipment monitoring in mind, the EN 12830 compliant Tinytag Transit 2 is a robust, lightweight temperature recorder. The unit's low profile means that it can be easily slipped into product packaging and the bright yellow casing allows it to be easily retrieved for collecting the temperature data. The Tinytag Transit loggers are ideal for monitoring shipments of pharmaceuticals, foodstuffs and many other products.

Tinytag Transit 2 Inductive Pad

The TG-4080 can be downloaded using either the USB cable, Ref CAB-0005-USB, or an inductive pad, Ref ACS-3030. The inductive pad allows many loggers to be quickly downloaded and doesn't require the casings to be opened or plugging in cables. The inductive pad also helps prevent condensation building up inside the casing when the loggers are deployed from a warm office.

 Features

  • Temperature Range: -40 to +70°C
  • Internal memory for up to 8,000 readings
  • Logging rates from 1 sec up to 10 days.
  • Highly visible bright yellow casing
  • 2 user programmable alarms
  • Delayed and trigger start options
  • IP54 splashproof casing
  • User replaceable battery
  • Cable and inductive pad connectivity
  • EN 12830 compliant

 

Popular Applications

  • Cold chain monitoring
  • Pharmaceutical transportation
  • Dry goods transportation

 

 Specifications
Memory Size 8,000 Readings
Resolution 0.01°C
Delayed Start Relative / Absolute (up to 45 days)
Stop Options When full, After No. of Readings or Never
Reading Types Actual, Minimum, Maximum
Logging Interval 1 second to 10 Days
Offload While stopped or in minute logging mode
Functional Range -40 to +70°C
IP Rating IP54 Splashproof
Battery Life Annual replacement advised
Dimensions Diameter 60.2mm x 15.3mm
Weight 28g

 

The link below takes you to the main Tinytag Transit logger page to view the related spares and accessories available for the Tinytag Transit data loggers.

Availability: Stock Item

 

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
Tinytag Transit 2 Starter Packs
TG-4080-SPK
TG-4080-SPK
Tinytag Transit 2 (TG-4080-SPK) Temperature Logger Starter Pack. Temperature range -40 to +70°C. Memory 8,000 readings with delayed and magnetic switch trigger start options, plus 2 programmable alarms. Logging intervals 1 sec to 10 days with min, max & actual readings. Data can be downloaded via the USB cable, or the ACS-3030 inductive pad. Each pack contains 1 x TG-4080, 1 x SWCD-0040 and 1 x CAB-0005-USB.
£95.00
or call us for a quote
 
Accessories
ACS-6000
ACS-6000
Trigger Start Magnet for various Tinytag data loggers. The magnet is ideal for delayed triggering of Tinytag loggers that have been set up for a trigger start. The magnet is merely passed over the correct location on the logger and the lights will start to flash showing that logging procedure has been started. The position of the unit’s trigger start switch is indicated by the • • • label on the back of the logger.
£10.00
or call us for a quote
 
Tinytag Inductive Pad
ACS-3030
ACS-3030
Tinytag USB inductive pad for configuring and downloading the Tinytag Splash 2, Aquatic 2 and Transit 2 loggers. The ACS-3030 inductive pad is the download connection for Tinytag inductive data loggers and is ideal for use in wet or harsh environments, or where large numbers of loggers are being programmed. It plugs into the PC via USB cable facilitating the offloading and configuration of multiple loggers without the need to directly connect a cable to the logger. Cable length 1m. This pad is supplied with a CD containing a copy of the Tinytag USB User Guide.
View FileDatasheet
   Size: (83.1 KB)
£35.00
or call us for a quote
 
Tinytag Starter Packs
SWPK-3-USB
SWPK-3-USB
Tinytag software and download cable starter pack. This starter pack contains USB inductive pad, Software CD, with device drivers, and an English, French, German, Italian, Spanish and Swedish quick start guide. This pack is suitable for use with the Tinytag Transit, Splash and Aquatic data loggers. The Tinytag software comes with a site licence allowing installation on multiple PCs at the same location, additional software should be purchased when used at a different site location.
View FileMinimum Specs
   Size: (281.92 KB)
£75.00
or call us for a quote
 
Tinytag Service Kits
SER-9514
SER-9514
Service Kit for Tinytag Transit 2 & CO2 data loggers. This kit contains a replacement battery and a service instruction sheet for the Transit 2 (TG-4080 & TG-4081) and CO2 (TGE-0010 & TGE-0011) data loggers.
£3.00
or call us for a quote