Contact our technical sales team now to discuss your requirement

( +44 (0) 845 9000 601  

*  info@omniinstruments.co.uk

( +1-866-849-3441  

*  info@omniinstruments.net

( +61 (0)282 442 363  

*  info@omniinstruments.com.au

Request a Quote

click here to send us your enquiry for our immediate attention

 
 
  Home  |  About Us  |  Terms and Conditions  |  Links  |  Sitemap |  Basket
 
 

 

Products

Data Loggers

Displacement Sensors

Display & Control Products

Flow Meters

Gas Detection Equipment

Gyros & Accelerometers IMU's & Tilt Sensors

Hire Equipment

Level Sensors

Load & Torque Sensors

Pressure Sensors

Radio & GSM Telemetry

Recorders - Chart

Stock Clearance Items

Temperature and Humidity

Test & Calibration

Vibration Monitoring

Voltage & Current Sensors

Weather Stations and Instruments

Omni Application Examples

 
 

Display & Control Products \ LCD and LED Displays \ Tracker 280 Digital Panel Indicator

 

«« previous product   10 / 10  

Tracker 280 Digital Panel Indicator

Digital Panel Indicator for Frequency, Timing, Counting, Batching, Rate, Measurement and Display. Universal Dual Input Channel Panel Indicator for Pulse, TTL, AC, Contact Closure and Encoder Signals Dual Universal Input Standard 1/8th DIN size Transducer Supplies Bright 6-Digit Display Isolated Analogue Output User Scaling For Frequency and Pulses User-Definable Panel Buttons Functions Serial Communications IP65 Front Panel Universal Mains Power Input Easy Stock Holding Up to 4 Alarm / Batch Control Outputs Totalisation to 12 Digits User-Definable Logic Inputs
 
 
 
 

 

 
 

Product details

 
 Tracker 280 Digital Panel Indicator

Digital Panel Indicator for Frequency, Timing, Counting, Batching, Rate, Measurement and Display
Universal Dual Input Channel Panel Indicator for Pulse, TTL, AC, Contact Closure and Encoder Signals

  • Dual Universal Input 
  • Standard 1/8th DIN size 
  • Transducer Supplies 
  • Bright 6-Digit Display 
  • Isolated Analogue Output 
  • User Scaling For Frequency and Pulses 
  • User-Definable Panel Buttons Functions 
  • Serial Communications 
  • IP65 Front Panel 
  • Universal Mains Power Input 
  • Easy Stock Holding 
  • Up to 4 Alarm / Batch Control Outputs 
  • Totalisation to 12 Digits 
  • User-Definable Logic Inputs 
     OPTIONS 
  • Green Display
  • 24 VDC/AC Power Supply 
 

Dual Universal Input
For most types of pulse and AC output sensors.

Tough but Attractive
The enclosure uses flame retardant (VO) materials and the front panel conforms to IP65.

Transducer Excitation Supplies
5V and 12VDC supplies are fitted as standard to power most sensor types.

Clear Display
The flat, slightly recessed 6-digit display together with high brightness red or green LED’s ensure maximum visibility even in difficult lighting conditions.

Universal Power Input
Wide ranging 90 to 265VAC input allows worldwide installation. A low voltage 24VAC/DC input option is available.

The Tracker 280 series of indicators are designed for demanding industrial applications for use with sensors that give AC or pulse outputs. The Tracker 280 Series can be used for measurement and display only applications or can act as a transmitter using the analogue output. The alarm option allows the Tracker 280 to be used as an alarm trip or batch controller. The unit is fitted with a serial communication interface as standard allowing it to be used as a front end device for PC-based systems. The combination of the dual universal inputs together with the power and flexibility of the software allows customers and distributors to reduce stock and spares inventory to a minimum. The Tracker 280 series are styled to match other indicators in the Tracker 200 range.

Applications include:
Pulse totalisation -Pulses are scaled to engineering units.
Pulse rate -Scaled pulses for rate (e.g. litres per minute)
Frequency measurement -Scalable for rate (e.g. rpm)
Up/Down counting Batch control
Position measurement with encoders
Encoder quadrature measurement
General timing

Applications

De-bounce is normally turned off for all sensor types except contact closure. This feature inhibits multiple counts which can be caused by contact bounce, and is selectable between 1 and 255 milliseconds in 1 millisecond steps.

Allows the input signal to be inverted.

Allows the input count, frequency or time to be converted into engineering units. Scale and Linearise also allows an eight-point user linearisation to be applied to compensate for non-linear sensor output signal rates, e.g. turbine flow meters.

Pre-Scaler for totalising values. This allows the totalled values to be in different engineering units, or at a different resolution, from the real-time measured value.

Low frequency cut off. This allows low input frequencies to be regarded as zero (user adjustable).

Batch Counter Control Functions
The Batch Controller functions are used for controlling batching type applications. The user can select from the following control modes:

Mode 1
On trigger, output 1 & 2 are turned OFF -unit counts (in engineering units) from a pre-set 'reset' value.
When batch setpoint 1 is reached, output 1 is turned ON -counts continue to be accumulated.
When batch setpoint 2 is reached, output 2 is turned ON -counts continue to be accumulated.
Unit waits for the next trigger, which must be toggled OFF then ON to reset the batch control.

Mode 2
On trigger, output 1 & 2 are turned OFF -unit counts (in engineering units) from a pre-set 'reset' value.
When batch setpoint 1 is reached, output 1 is turned ON -counts continue to be accumulated.
When batch setpoint 2 is reached, O/P 2 is turned ON and O/P 1 OFF -counts continue to be accumulated.
Unit waits for the next trigger, which must be toggled OFF then ON to reset the batch control.

Mode 3
On trigger, output 1 & 2 are turned OFF -unit counts (in engineering units) from a pre-set 'reset' value.
When batch setpoint 1 is reached, output 1 is turned ON -counts continue to be accumulated.
When batch setpoint 2 is reached, output 2 is turned ON -counts continue to be accumulated.
Automatic re-trigger will occur if the trigger state is correct (no need to toggle trigger).
Counts continue to be accumulated.

Mode 4
On trigger, output 1 & 2 are turned OFF -unit counts (in engineering units) from a pre-set 'reset' value.
When batch setpoint 1 is reached, output 1 is turned ON -counts continue to be accumulated.
When batch setpoint 2 is reached, O/P 2 is turned ON and O/P 1 OFF -counts continue to be accumulated.
Automatic re-trigger will occur if the trigger state is correct (no need to toggle trigger).
Counts continue to be accumulated.
 
 
 

Features
Dual Universal Inputs
The Tracker 280 can be directly connected to most popular process sensors including AC magnetic pickups and pulse output devices. All input types can be scaled to display values in the user's preferred engineering units. The user can select to use the internal crystal controlled clock or calibrate to a known external standard. Transducer excitation is provided as standard giving 5 or 12VDC. An 8 point user linearisation can be used to compensate for non-linear sensor outputs for frequency and timing applications. Encoder measurement offers bi-directional pulse counting. A further four times resolution is available when used in quadrature mode.

Serial Communications
All Tracker 280 series indicators are supplied with RS422/485 serial communications as standard. This interface allows computer-based systems to read values (e.g. the measured value) and write values (e.g. alarm setpoints) to and from the instrument. The Tracker 280 has three protocols including the widely used MODBUS-RTU (J-BUS).

Alarm and Batching Control Outputs (T284 & T285)
The Tracker 284 is fitted with two relay outputs and the Tracker 285 has four TTL outputs. Setpoints can be adjusted at the time of configuration and can be password protected or adjusted using the buttons on the front panel. Each alarm can be used in High, Low or Deviation mode. Outputs can be configured to give a pulse for a user selectable time period, and can be latching with independent delay times for both on and off conditions. In addition they can be set to be energised or de-energised when in the alarm condition or when a batch (count) value is reached.

Analogue Output
The measured value can be transmitted as a 0 to 10 Volt, 0 to 20mA or 4 to 20mA signal to other devices such as chart recorders or data loggers. The fully isolated output can be scaled for any portion of the display range e.g. 4 to 20 mA = 500.00 to 800.00 (Litres/m). The analogue output can be configured to re-transmit rate, time or totalised (6 LSD) values.

 

Components / Downloads

 
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
 

ref

description

downloads

price (£)

Order Item

T283-1-R

Digital Panel Indicator for Frequency, Timing, Counting, Batching, Rate, Measurement and Display. Universal Dual Input Channel Panel Indicator for Pulse, TTL, AC, Contact Closure and Encoder Signals. Dual Universal Input, Standard 1/8th DIN size, Transducer Supplies, Bright 6-Digit Display, Isolated Analogue Output, User Scaling For Frequency and Pulses, User-Definable Panel Buttons Functions, Serial Communications, IP65 Front Panel, Universal Mains Power Input, Easy Stock Holding, Up to 4 Alarm / Batch Control Outputs, Totalisation to 12 Digits, User-Definable Logic Inputs. Power supply 90-265 VAC, red display.

 

Data sheet

 

265.00

 

or call us for a quote

T284-1-R

Digital Panel Indicator for Frequency, Timing, Counting, Batching, Rate, Measurement and Display. Universal Dual Input Channel Panel Indicator for Pulse, TTL, AC, Contact Closure and Encoder Signals. Dual Universal Input, Standard 1/8th DIN size, Transducer Supplies, Bright 6-Digit Display, Isolated Analogue Output, User Scaling For Frequency and Pulses, User-Definable Panel Buttons Functions, Serial Communications, IP65 Front Panel, Universal Mains Power Input, Easy Stock Holding, Up to 4 Alarm / Batch Control Outputs, Totalisation to 12 Digits, User-Definable Logic Inputs, dual alarm output. Power supply 90-265VAC, red display

 

300.00

 

or call us for a quote

T285-1-R

Digital Panel Indicator for Frequency, Timing, Counting, Batching, Rate, Measurement and Display. Universal Dual Input Channel Panel Indicator for Pulse, TTL, AC, Contact Closure and Encoder Signals. Dual Universal Input, Standard 1/8th DIN size, Transducer Supplies, Bright 6-Digit Display, Isolated Analogue Output, User Scaling For Frequency and Pulses, User-Definable Panel Buttons Functions, Serial Communications, IP65 Front Panel, Universal Mains Power Input, Easy Stock Holding, Up to 4 Alarm / Batch Control Outputs, Totalisation to 12 Digits, User-Definable Logic Inputs. Quad TTL alarm O/P. Power supply 90-265VAC, red display.

 

300.00

 

or call us for a quote

 
 
 

 Tel +44 (0) 845 9000 601  Fax +44 (0) 845 9000 602 info@omniinstruments.co.uk        Tel +1-866-849-3441  Fax +1-866-628-8055  info@omniinstruments.net 

  Tel +61 (0)282 442 363  Fax +61 (0)294 751 278  info@omniinstruments.com.au

| Home  |  About Us  |  News / New Products  |  Old Omni Site  |  Terms and Conditions  |  Links  |  Sitemap | Web Design |