Contact our technical sales
team now to discuss your
requirement

+44 (0) 845 9000 601
info@omni.uk.com
Click here to order your Omni Instruments 2010 Calendar           
Request a quote
click here to send us your inquiry for our immediate attention
 
Basket My Account
Home About Us Employment Links Sitemap  
 
Data Loggers - Temp / RH Acceleration & Pressure
Data Loggers - Industrial General Purpose
Data Acquisition Systems High Speed & PC
Displacement Sensors
Display & Control Products
Flow Meters
Gas Detection Equipment
Gyros & Accelerometers IMU's & Tilt Sensors
Hire Equipment
Level Sensors
Load & Torque Sensors
Pressure Sensors
Radio & GSM Telemetry
Recorders - Chart
Serial & Ethernet Communications
Solar & Wind Power Batteries & Enclosures
Temperature and Humidity
Test & Calibration
Vibration Monitoring
Voltage & Current Sensors Energy Monitoring Systems
Water Quality Sensors
Weather Stations and Instruments
Omni Application Examples
 

 

Flow Meters \ Ultrasonic Flowmeters - Fixed - Time of Flight and Doppler \ OMNI-TUF-200F Wall Mount Ultrasonic Flowmeter

 

«« previous product   2 / 5   next product »»

OMNI-TUF-200F Wall Mount Ultrasonic Flowmeter

This low cost clamp on ultrasonic flowmeter is ideal for long-term deployment for flow measurement and closed-pipe applications, such as liquid process control, water flow measurement (hot/chill water, city water, sea water), sewage and sludge measurement, and measurements of oil (crude/diesel/fuel), chemicals (alcohol, acids, etc.), beverage, and many other liquids. Once the sensors are clamped on the pipe using the supplied stainless steel straps it can be programmed in a matter of minutes via the front keypad. In addion to the 4-20mA and pulse outputs the unit can also communicate via GSM modem.
 
 
 
 

Stock Item

 
 
Downloads

Send page to a colleague

 

 
 

Product details

 

OMNI-TUF-200F Wall Mount Ultrasonic Flowmeter supplied with transducers for pipe sizes 15-100mm or 100 - 700mm, complete with manual and stainless steel straps.

Features:

  • High accuracy. Normally, ±1%. When on-site calibration available, ±0.5%.
  • Wide flow range 0.03 to 105ft/s.
  • Wide pipe size range (from 1" to 240").
  • Noninvasive. No pipe disturbance. No moving parts, no pressure drop.
  • Easy and economical installation. No cutting pipe, non drilling hole.
  • Suitable for all commonly used pipe materials
  • Easy to use and set up. Self-explanatory menu programming
  • Velocity, volumetric and totalized flow
  • GPRS / GSM networking capability with certain model
  • Ideal for both clean and opaque liquid flow measurements

Specification
Linearity 0.5%
Repeatability 0.2%
Accuracy Normally better than ±1%. Could be ±0.5% with on-site calibration.
Response Time 0.5 Seconds
Display Backlit LCD 2x20 Characters.
Display instantaneous flow rate, accumulated flow rate (positive, negative and net rates), velocity, time, analog inputs, etc.
Units English (U.S.) or metric
Signal Outputs Current output: 4-20mA or 0-20mA. Impedance 0-1k
  OCT output: pulse signal for accumulated flow rate (positive, negative and net rates); frequency signal for instantaneous flow rate (0-9,999Hz selectable)
  Relay: output 20 signals, such as no signal, reverse flow & more
Signal Inputs 5 channel analog signal inputs (for signals such as temperature, pressure, liquid level, etc.)
Data Logger Automatically record the following information:
1) The totalizer data of the last 64 days / 64 months / 64 years
2) The power time and corresponding flow rate of the last 64 times power on and off events
3) Allow manual or automatic flow loss compensation
4) The instrument working status of the last 64 days.
Computer Interface RS232
Enclosure Protection Class: IP65 (NEMA 4X)
Liquids Type: Virtually all commonly used liquids (full pipe)
Temperature: 32˚F - 212˚F (0˚C - 100˚C)
Concentration: <10,000ppm and small air bubble concentration
Pipe Sizes: 1" - 240"
Materials: All metals, most plastics, fiber glass, etc.
Pipe Length: Better longer than 15D, where D is pipe diameter. If a pump is near, the straight pipe section following the pumps should be > 30D
Cable Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power lines, neither should it be close to strong interference source such as power transformers.
Power 8 to 36VDC, 80 to 265VAC optional with PSU

 

Transducer Specifications
Type S1 Small size transducer (magnetic)
For pipe size ½” – 4”
Type M1 Standard medium size transducer (magnetic)
For pipe size 2” – 28”
Type L1 Large size transducer (magnetic)
For pipe size 11” – 240”

 

Components / Downloads

 
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
 

ref

description

downloads

price (£)

Order Item

OMNI-TUF-200F-3-5-ADAR

OMNI-TUF-200F Wall Mount Ultrasonic Flowmeter supplied with Medium transducers for pipe sizes 100 - 700mm, complete with 5 metres of cable, manual and stainless steel straps.

 

Manual

 

Data Sheet

 

1694.97

 

or call us for a quote

OMNI-TUF-200F-1-5-ADAR

OMNI-TUF-200F Wall Mount Ultrasonic Flowmeter supplied with transducers for pipe sizes 25 - 100mm, complete with 5 Metre cable set, manual and stainless steel straps.

 

1695.00

 

or call us for a quote

Spares and Replacement Parts 

 
 
 


 
+44 (0) 845 9000 601
    +44 (0) 845 9000 602
    info@omni.uk.com
+1-866-849-3441
    +1-866-628-8055
    info@omniinstruments.net
+61 (0)282 442 363
    +61 (0)294 751 278
    info@omniinstruments.com.au
Copyright © 2009 - Omniinstruments Home | About Us | News / New Products | Old Omni Site | Terms and Conditions | Links | Sitemap | Web Design