The LFT range of Turbine Flowmeters meet the demands of most liquid measurement applications. They are well suited to the measurement of low viscosity lubricating and non-lubricating fluids, although versions for slurry applications are available. A high degree of accuracy and repeatability are attainable using this time served flowmetering principle, which is easily field serviced and re-calibrated. Available in sizes 1/2" up to 6" with optional intrinsic safety and LCD rate / totaliser display.
The Rotor blades sweep out the full bore of the meter except for a small tip clearance space . As the blade tips pass the magnetic pick up they initiate a pulse . Flow rate is determined by the frequency of the pulses and Totalised Flow is obtained by summing the pulses .
“ Fluidwell “ Totalisers , which sum the pulses automatically and display Flow Rate and Total Flow instantly on the readout , can be mounted on the Turbine or fitted remotely . Options include: linearisation, pulse/4-20 retransmit , batch control, RS comms, with various power options including 7 year Battery. (EEx ia versions available)
Linearity : + / - 0.5 % ( better than + / - 0.2 % when used with “Fluidwell “ Totaliser ) . Repeatability : + / - 0.1 % . Temperature : - 30 oC to + 120 oC ( maximum + 350 oC with optional High Temperature Pick Up ) . Pressure Drop : 250 mbar at maximum quoted Flow rate .
Code/Style
BSP : BSPP Male Threaded . NPT : NPT Male Threaded . FL1 : ANSI 150 Flanged . FL2 : ANSI 300 Flanged . FL3 : BS 4504 ( DIN ) PN16 . FL4 : BS 4504 ( DIN ) PN25 . WAF : Wafer . TRI : Tri – Clamp .
Example Options
HT : High Temperature Pick Up . IS : Intrinsically Safe Pick Up . 2P : Second Pick Up fitted .
LFT Turbines fitted with the intrinsically safe pick up ( IS option ) are suitable for Hazardous Installations ( Eex ia IIC T4 ) .
F112 Flow Rate Totaliser unit can be fitted to the LFT turbine meter series to provide and flow rate and total display, 4-20mA flow rate output, and pulse output for flow total.
For further information,
technical advice, or a
quotation please call or
email
us. If you are not sure which
product you need one of our
technical sales advisors will be
happy to discuss your
application. We also accept
company purchase orders by fax
or post. Credit card orders can
also be placed over the phone
for any product.
ref
description
downloads
price(£)
Order Item
LFT/½"Low/BSP
½" Liquid Flow Turbine 2 - 10 L/min, St/Steel Construction, Screwed Connections
Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)
½" Liquid Flow Turbine 2-20 L/min St/Steel Construction, Screwed Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)
695.00
LFT/¾"Low/BSP
¾" Liquid Flow Turbine 14 - 140 L/min St/Steel Construction, Screwed Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option
595.00
LFT/¾"High/BSP
¾" Liquid Flow Turbine 14 - 140 L/min St/Steel Construction, Screwed Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)
595.00
LFT/1"/BSP
1" Liquid Flow Turbine 27 - 270 L/min St/Steel Construction, Screwed Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)
659.00
LFT/1½"/BSP
1½" Liquid Flow Turbine 55 - 550 L/min St/Steel Construction, Screwed Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)
695.00
LFT/2"/BSP
2" Liquid Flow Turbine 114 - 1140 L/min St/Steel Construction, Screwed Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)
759.00
LFT/4"/FL
" Liquid Flow Turbine 454 - 4540 L/min St/Steel Construction, Flanged Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)
1750.00
LFT/6"/FL
6" Liquid Flow Turbine 909 - 9080 L/min St/Steel Construction, Flanged Connections Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)
2455.00
F110-P-HD