Contact our technical sales team now to discuss your requirement

( +44 (0) 845 9000 601  

*  info@omniinstruments.co.uk

( +1-866-849-3441  

*  info@omniinstruments.net

( +61 (0)282 442 363  

*  info@omniinstruments.com.au

Request a Quote

click here to send us your enquiry for our immediate attention

 
 
  Home  |  About Us  |  Terms and Conditions  |  Links  |  Sitemap |  Basket
 
 

 

Products

Data Loggers

Displacement Sensors

Display & Control Products

Flow Meters

Gas Detection Equipment

Gyros and Accelerometers

Hire Equipment

Level Sensors

Load & Torque Sensors

Pressure Sensors

Radio & GSM Telemetry

Recorders - Chart

Stock Clearance Items

Temperature and Humidity

Test & Calibration

Vibration Monitoring

Voltage & Current Sensors

Weather Stations and Instruments

Omni Application Examples

 
 

Flow Meters \ Turbine and Paddle Wheel Flowmeters \ LFT Stainless Steel Turbine Meter Range

 

«« previous product   2 / 4   next product »»

LFT Stainless Steel Turbine Meter Range

The LFT range of Turbine Flowmeters meet the demands of most liquid measurement applications. They are well suited to the measurement of low viscosity lubricating and non-lubricating fluids, although versions for slurry applications are available. A high degree of accuracy and repeatability are attainable using this time served flowmetering principle, which is easily field serviced and re-calibrated. Available in sizes 1/2" up to 6" with optional intrinsic safety and LCD rate / totaliser display.

Hazardous Area Approved

 
 
 
 

 

 
 

Product details

 

Technique

The Rotor blades sweep out the full bore of the meter except for a small tip clearance space . As the blade tips pass the magnetic pick up they initiate a pulse . Flow rate is determined by the frequency of the pulses and Totalised Flow is obtained by summing the pulses .

“ Fluidwell “ Totalisers , which sum the pulses automatically and display Flow Rate and Total Flow instantly on the readout , can be mounted on the Turbine or fitted remotely . Options include: linearisation, pulse/4-20 retransmit , batch control, RS comms, with various power options including 7 year Battery. (EEx ia versions available)

GENERAL SPECIFICATIONS

Materials
Body : 316 Stainless Steel .
Rotor Supports : 316 Stainless Steel .
Journal Bearings : Tungsten Carbide .
Thrust Ball : 316 Stainless Steel .
Rotor : ANC1A Stainless Steel .
Rotor Shaft : Tungsten Carbide . BSP WAF

Performance

Linearity : + / - 0.5 % ( better than + / - 0.2 % when used with “Fluidwell “ Totaliser ) .
Repeatability : + / - 0.1 % .
Temperature : - 30 oC to + 120 oC ( maximum + 350 oC with optional High Temperature Pick Up ) .
Pressure Drop : 250 mbar at maximum quoted Flow rate .

Code/Style

BSP : BSPP Male Threaded . NPT : NPT Male Threaded .
FL1 : ANSI 150 Flanged . FL2 : ANSI 300 Flanged .
FL3 : BS 4504 ( DIN ) PN16 . FL4 : BS 4504 ( DIN ) PN25 .
WAF : Wafer . TRI : Tri – Clamp .

Example Options

HT : High Temperature Pick Up .
IS : Intrinsically Safe Pick Up .
2P : Second Pick Up fitted .

LFT Turbines fitted with the intrinsically safe pick up ( IS option ) are suitable for Hazardous Installations ( Eex ia IIC T4 ) .

 

 

 

F112 Flow Rate Totaliser unit can be fitted to the LFT turbine meter series to provide and flow rate and total display, 4-20mA flow rate output, and pulse output for flow total.

 

 

 

 

 

Components / Downloads

 
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
 

ref

description

downloads

price(£)

Order Item

LFT/½"Low/BSP

½" Liquid Flow Turbine 2 - 10 L/min, St/Steel Construction, Screwed Connections Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)

 

Data Sheet

 

579.00

 

or call us for a quote

LFT/½"High/BSP

½" Liquid Flow Turbine 2-20 L/min St/Steel Construction, Screwed Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)

 

695.00

 

or call us for a quote

LFT/¾"Low/BSP

¾" Liquid Flow Turbine 14 - 140 L/min St/Steel Construction, Screwed Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option

 

595.00

 

or call us for a quote

LFT/¾"High/BSP

¾" Liquid Flow Turbine 14 - 140 L/min St/Steel Construction, Screwed Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)

 

595.00

 

or call us for a quote

LFT/1"/BSP

1" Liquid Flow Turbine 27 - 270 L/min St/Steel Construction, Screwed Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)

 

659.00

 

or call us for a quote

LFT/1½"/BSP

1½" Liquid Flow Turbine 55 - 550 L/min St/Steel Construction, Screwed Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)

 

695.00

 

or call us for a quote

LFT/2"/BSP

2" Liquid Flow Turbine 114 - 1140 L/min St/Steel Construction, Screwed Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)

 

759.00

 

or call us for a quote

LFT/4"/FL

" Liquid Flow Turbine 454 - 4540 L/min St/Steel Construction, Flanged Connections. Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)

 

1750.00

 

or call us for a quote

LFT/6"/FL

6" Liquid Flow Turbine 909 - 9080 L/min St/Steel Construction, Flanged Connections Accuracy (within linear range) : + / - 0.5 %, better than 0.2 % when used with “ F112-P” Rate/Totaliser , Repeatability : + / - 0.1 % , Temperature : - 30ºC to + 120ºC (350ºC Option)

 

2455.00

 

or call us for a quote

F110-P-HD

Fluidwell F 1 series flowrate totaliser, LDC display, with pulse and analogue ( 4-20mA) O/P, 24vDC, loop powered, ABS field mounting enclosure ( panel or direct mounting ).

 

Data Sheet

 

325.00

 

or call us for a quote

 
 
 