Contact our technical sales team now to discuss your requirement

( +44 (0) 845 9000 601  

*  info@omniinstruments.co.uk

( +1-866-849-3441  

*  info@omniinstruments.net

( +61 (0)282 442 363  

*  info@omniinstruments.com.au

Request a Quote

click here to send us your enquiry for our immediate attention

 
 
  Home  |  About Us  |  Terms and Conditions  |  Links  |  Sitemap |  Basket My Account 
 
 

 

Products

Data Loggers

Displacement Sensors

Display & Control Products

Flow Meters

Gas Detection Equipment

Gyros & Accelerometers IMU's & Tilt Sensors

Hire Equipment

Level Sensors

Load & Torque Sensors

Pressure Sensors

Radio & GSM Telemetry

Recorders - Chart

Stock Clearance Items

Temperature and Humidity

Test & Calibration

Vibration Monitoring

Voltage & Current Sensors

Weather Stations and Instruments

Omni Application Examples

 
 

Data Loggers \ Graphtec Midi Data Logger Range \ GL200 Midi Data Logger

 

1 / 4   next product »»

GL200 Midi Data Logger

Compact ten channel data logger with a 3.5" color display, keypad, logs to USB memory stick , internal memory or to PC via the USB 2 computer interface. The unit has signal inputs for thermocouples, RTD's, 4-20mA and voltage ranges from 0- 20mV to 0-50V with 16 bit resolution. Sample rates can be set from from 100ms up to 1 hour and the unit has 3.5MB of internal memory. it is avaialble with standard AC voltage power supply or optional rechargeable battery pack.
 
 
 
 

Stock Item

 
 
Downloads

Send page to a colleague

 

 
 

Product details

 

This hand held data logger provides a real time graph display, up to 10 input channels, with data logging to internal memory, USB stick or direct to your PC. It is very easy to setup and use via the integral keypad, making it ideal for site tests.

ItemGL200
Number of analog input 10 channels
Input Method Photo MOS relay scanning system; all channels isolated
Measurement Ranges Voltage 20, 50, 100 500mV; 1, 2, 5, 10, 20, 50V ; 1-5 v F.S.
Temperature Thermocouples: K, J, E, T, R, S, B, N, W(WRe5-26)
Humidity 0 to 100% (Voltage 0V to 1V scaling conversion)
Filter Off, 2,5,10,20,40 Filter operation is on a moving average basis. The average value of the set sampling count is used.
Scan Speed 0.1s/10 Ch Maximum
Trigger Functions Repeat Trigger Off, On
Trigger Types Start/Stop: Data capture starts/stops when a trigger is generated.
Trigger Conditions •Start: Off, Level, External digital, Date
•Stop: Off, Level, External digital, Date,Time
Alarm Judgement modes • Analog: H, L, Window In, Window Out • Logic: H,L •Pulse: H, L, Window In, Window Out
Alarm output Output format Open Collector output (100 k Ohm pull-up resistance)
Output Conditions Level judgement, window judgement, logic pattern judgement, pulse judgement
Pulse/Logic Input Pulse input: 1ch/ Logic input:1ch
Pulse input Revolutions mode Spans 50, 500, 5000, 50k, 500k, 5M, 50M 500M RPM
Counts Mode Spans 50, 500, 5000, 50k, 500k, 5M, 50M 500M Counts/sec
Inst. Mode Spans 50, 500, 5000, 50k, 500k, 5M, 50M 500M Counts/ec
Max number of pulse inputs Counts, Inst modes: 50k/sampling interval • Revs 50k/s
PC interface USB (Ver.1.1)
Internal memory devices Memory capacity • Internal memory: 3.5MB • USB memory: Depends on the type of memory used
Memory contents • Setup conditions • Measured data • Screen copy
Statistical calculation Types of operation Average value, peak value, maximum value, minimum value, RMS
Number of operations 2 can be set simultaneously
Method Realtime operation
Note: When the Digital screen + Calculation Display screen has been specified, the calculation results are displayed.
Search functions Search the captured data for the required number of points
Scaling function 4 points can be set for each channel
Display Size 3.5'' TFT colour LCD (320 x 240 dots)
Display screen Waveform display Waveform screen + digital screen, Waveform screen
Digital display Waveform screen + digital screen, digital screen + Calculation Display screen
A/D Converter 16bits(out of which 14 are internally acknowledged)
Maximum permissible input voltage Between +/- terminals: 60Vp-p •Between input terminals and casing: 60Vp-p
Input Impedance 1M Ohm ±5%
Withstand Voltage Between each input channel and main unit chassis, and also between each CHs: 1minute at 350V p-p
Operating Environment 0 to 40°C, 30 to 80% RH
Power Supply AC adapter 100 to 240 VAC, 50/60 Hz
DC input 8.5 to 24 VDC)
Battery pack (optional) 7.4VDC (2200mAh)
Power consumption 28 VA or lower (AC drive)
External Dimensions 194 x 122 x 41 mm
Weight 480g (excluding the AC adapter and battery)

 

Components / Downloads

 
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
 

ref

description

downloads

price (£)

Order Item

GL200

Data logger with 3.5" color display, 10 channels, 3.5MB of internal memory, USB flash drive support, 16 bit resolution, isolated inputs. Includes software and cables.

 

Data Sheet

 

795.00

 

or call us for a quote

B-517

Battery pack, lasts for 6 hours on a single charge

 

95.00

 

or call us for a quote

B-514

DC power cable, 2 meters long, direct connection to power source

 

50.00

 

or call us for a quote

B-530

Humidity Sensor, 0 - 100% RH

 

285.00

 

or call us for a quote

 
 
 