Omni Instruments
contact icon+44 (0) 1382 443000
+44 (0) 845 9000 601
WE ARE HERE TO HELP

Contact our technical sales team now to discuss your requirements

help icon
MY BASKET basket arrow

£0.00

My Cart

You have no items in your shopping cart.

Click basket to edit.

Products

Latest added news blog
MSR175 Shock Transportation Data Logger
Kenny Laidlaw
Oct 01,2018
The MSR175 shock transportation data logger is the newest miniature logger from MSR.  The MSR175 ut...read more >
Pace Scientific Thermocouple/mV Input Module
  • Pace Scientific Thermocouple/mV Input Module

Pace Scientific Thermocouple/Millivolt Modules

Quick Overview

Mvt modules enable the XR440 and XR450 Data Loggers to accept a millivolt or thermocouple input on channel 3. The Mvt-20u, Mvt-100u, Mvt-107b and Mvt-500u are used solely for mV inputs but three modules (Mvt-11b, Mvt-22b, Mvt-50u) can be used for mV or thermocouple inputs (Type J, K, N, R, S, T, B, C, or E). A built-in precision thermistor on channel 1 provides ambient temperature readings and thermocouple cold junction compensation. An Mvt module configures the logger as follows: Ambient temperature on channel 1. Millivolt (or thermocouple) signal on channel 3. Channels 2 and 4 are 'Standard' channels and will accept Pace sensors, 0-5vDC or resistive signals.

View Options

Details

The MVT modules will configure the Pace Scientifiic Pocket Logger as follows:

Channel 1: Ambient Temperature.*
Channel 3: MilliVolt or Thermocouple Input.
Channels 2 and 4: ‘Standard’ channels, suitable for any Pace sensors, 0-5vDC or resistive inputs.

*A built-in, precision thermistor provides ambient temperature readings and cold junction compensation for thermocouple inputs.

Specifications

 

Operating Temperature: -40 to 60°C (-40 to 140°F)
Module Size: 41mm wide x 19mm deep x 14mm high
Overall Size with XR440: Adds 9mm to loggers overall length, no change to height and width
Thermistor Sensor: ±0.1°C interchangeability, 0-70°C
Input Type: Single ended, (-) terminal is internally connected to dc ground
Input Impedance: Greater than 10 M ohm

Note: The last letter of the model number ('u' or 'b') signifies unipolar or bipolar input.

Electrical Specifications

Model Mvt-11b Mvt-22b Mvt-20u Mvt-50u Mvt-100u Mvt-107b Mvt-500u
Range ±11 mV ±22 mV 0-20 mV 0-50 mV 0-100 mV ±107 mV 0-500 mV
Resolution (12 bit) 12 µV 24 µV 5 µV 12 µV 24 µV 120 µV 120 µV
Offset Voltage 200 µV max. 200 µV max. 5 µV max. 5 µV max. 5 µV max. 200 µV max. 5 µV max.
Offset Voltage Drift 2 µV/ °C max. 2 µV/ °C max. 0.05 µV/ °C max. 0.05 µV/ °C max. 0.05 µV/ °C max. 2 µV/ °C max. 0.05 µV/ °C max.
Accepts Thermocouple Yes Yes No Yes No No No
System Accuracy 0.8% of F.S. 0.8% of F.S. 0.4% of F.S. 0.4% of F.S. 0.4% of F.S. 0.8% of F.S. 0.4% of F.S.

 

Thermocouple Specifications for Mvt-11b, Mvt-22b, and Mvt-50u

Mvt-11b Thermocouple Specifications

Type Min. Temperature Max. Temperature Approx. Resolution
J -130°C (-202°F) 200°C (392°F) 0.2°C (0.4°F)
K -250°C (-418°F) 270°C (518°F) 0.3°C (0.5°F)
N -50°C (-58°F) 340°C (644°F) 0.3°C (0.5°F)
R 0°C (32°F) 1030°C (1886°F) 0.8°C (1.4°F)
S 0°C (32°F) 1120°C (2048°F) 1.0°C (1.8°F)
T -200°C (-328°F) 230°C (446°F) 0.2°C (0.4°F)
B 0°C (32°F) 1570°C (2858°F) 1.0°C (1.8°F)
C 0°C (32°F) 620°C (1148°F) 0.6°C (1.1°F)
E -100°C (-148°F) 160°C (320°F) 0.15°C (0.3°F)

 

Mvt-22b Thermocouple Specifications

Type Min. Temperature Max. Temperature Approx. Resolution
J -130°C (-202°F) 400°C (752°F) 0.4°C (0.7°F)
K -250°C (-418°F) 530°C (986°F) 0.6°C (1.1°F)
N -50°C (-58°F) 630°C (1166°F) 0.6°C (1.1°F)
R 0°C (32°F) 1760°C (3200°F) 1.6°C (2.9°F)
S 0°C (32°F) 1760°C (3200°F) 2.0°C (3.6°F)
T -200°C (-328°F) 400°C (752°F) 0.4°C (0.7°F)
B 0°C (32°F) 1820°C (3308°F) 2.0°C (3.6°F)
C 0°C (32°F) 1210°C (2210°F) 1.2°C (2.2°F)
E -100°C (-148°F) 310°C (590°F) 0.3°C (0.5°F)


Mvt-50u Thermocouple Specifications

Type Min Temp Max Temp Approx. Resolution
J Ambient* 760°C (1400°F) 0.2°C (0.4°F)
K Ambient* 1220°C (2228°F) 0.3°C (0.5°F)
N Ambient* 1300°C (2372°F) 0.3°C (0.5°F)
R Ambient* 1760°C (3200°F) 0.8°C (1.4°F)
S Ambient* 1760°C (3200°F) 1.0°C (1.8°F)
T Ambient* 350°C (662°F) 0.2°C (0.4°F)
B Ambient* 1820°C (3308°F) 1.0°C (1.8°F)
C Ambient* 2320°C (4208°F) 0.6°C (1.1°F)
E Ambient* 660°C (1220°F) 0.15°C (0.3°F)
J 'low' -130°C (-202°F) Ambient* 0.2°C (0.4°F)
K 'low' -250°C (-418°F) Ambient* 0.3°C (0.5°F)
N 'low' -50°C (-58°F) Ambient* 0.3°C (0.5°F)
T 'low' -200°C (-328°F) Ambient* 0.2°C (0.4°F)
E 'low' -100°C (-148°F) Ambient* 0.15°C (0.3°F)

*Ambient temperature of Mvt-50u

Mvt-50u Thermocouple Limitation

The Mvt-50u must be set (in Pocket Logger Software) to read either high or low temperatures.  When set for high temperatures, the low temperature limit is the ambient temperature of the Mvt Module.  When set for low temperatures, the high temperature limit is the ambient temperature of the Mvt Module.  The Mvt-11b and Mvt-22b do not have this limitation.

Availability: Stock Item

 

Related Products

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
XR440 Thermocouple/Millivolt Input Modules
MVT-11B
MVT-11B

MVT11B Thermocouple / Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV or Thermocouple Inputs, mV Range: ±11mV with a 12µV resolution. Thermocouple Input suitable for Type J, K, N, R, S, T, B, C, E Thermocouples. Module adds 9mm to overall length of an XR440.

£142.37
or call us for a quote
MVT-22B
MVT-22B

MVT22B Thermocouple / Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV or Thermocouple Inputs, mV Range: ±22mV with a 24µV resolution. Thermocouple Input suitable for Type J, K, N, R, S, T, B, C, E Thermocouples. Module adds 9mm to overall length of an XR440.

£142.37
or call us for a quote
MVT-50U
MVT-50U

MVT50U Thermocouple / Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV or Thermocouple Inputs, mV Range: 0-50mV with a 12µV resolution. Thermocouple Input suitable for Type J, K, N, R, S, T, B, C, E Thermocouples. Thermocouple input will read either high or low temperatures relative to ambient temperature reading. Module adds 9mm to overall length of an XR440.

£142.37
or call us for a quote
 
XR440 Millivolt Input Modules
MVT-20U
MVT-20U

MVT20U Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV Inputs, mV Range: 0-20mV with a 5µV resolution. Module adds 9mm to overall length of an XR440.

£142.37
or call us for a quote
MVT-100U
MVT-100U

MVT100U Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV Inputs, mV Range: 0-100mV with a 24µV resolution. Module adds 9mm to overall length of an XR440.

£142.37
or call us for a quote
MVT-107B
MVT-107B

MVT107B Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV Inputs, mV Range: ±107mV with a 120µV resolution. Module adds 9mm to overall length of an XR440.

£142.37
or call us for a quote
MVT-500U
MVT-500U

MVT500U Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV Inputs, mV Range: 0-500mV with a 120µV resolution. Module adds 9mm to overall length of an XR440.

£142.37
or call us for a quote