The MicroCal 2 & 3 thermocouple simulator helps ensure that the frequent checking of thermometer accuracies is a routine operation. The thermometer calibrator designed to simulate a chosen temperature, allowing standard K, J or T thermocouple thermometers to be tested or recalibrated simply and quickly, without the need for additional specialised equipment or conversion tables. It features a custom 10mm LCD display with alpha-numeric display line to prompt the user when changing parameters. Selectable parameters include; C/F, auto power off - enable/disable, CJC - internal/external and display contrast adjustment.
View Options

Details

The MicroCal ensures that the frequent checking of thermometer accuracies is a simple routine operation.

The instrument is designed to simulate any chosen temperature, allowing standard K, J or T thermocouple thermometers to be tested, checked or recalibrated simply and quickly, without the need for additional specialised equipment or conversion tables.

The MicroCal 2 has 12 preset temperatures which can be modified and saved by the user. The factory default temperatures can be recalled at any time. The MicroCal 3 has 23 fixed temperatures. Both models feature a custom 10mm LCD display with alpha-numeric display line to prompt the user when changing parameters. Selectable °C/°F, auto off enable/disable and display contrast adjustment are also available.

Each MicroCal is supplied with a one metre PVC lead with miniature thermocouple connector and a five-point UKAS Certificate of Calibration. Each certificate indicates deviations from standards at the various check points.

Specifications<

Version MicroCal 2 MicroCal 3
Temperature Range 12 Adjustable 23 Fixed
Accuracy ±0.3°C ±0.5°C
Sensor Type Dedicated K, J or T Type Thermocouples
Ambient Temp Range 0 to 50°C
CJC Type PT100
Battery 2 x MN2400 (AAA)
Battery Life 300 Hours
Display Custom LCD
Case Dimensions 141 x 73 x 35mm (hxwxd)
Case Material Black ABS Plastic
Weight 175 grams

 

 

Availability: Stock Item

 

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
MicroCal 2 Simulators
271-200

The MicroCal 2 K-Type Thermocouple Simulator helps to ensure the frequent checking of thermometer accuracies is a routine operation. Designed to simulate a chosen temperature to test K-Type Thermocouple thermometers. It has 12 adjustable temperature points (-20, -10, 0, +10, +30, +50, +100, +195, +250, +500, +800 and +1000°C). Battery Powered, 2 x AAA Alkaline batteries (life 300 Hours). Comes with a five point UKAS Certificate of Calibration which indicates deviations from standards at the various points and a one meter PVC type K thermocouple lead with miniature connector.

View FileDatasheet
   Size: (1.26 MB)
£140.00
or call us for a quote
271-201

The MicroCal 2 J-Type Thermocouple Simulator helps to ensure the frequent checking of thermometer accuracies is a routine operation. Designed to simulate a chosen temperature to test J-Type Thermocouple thermometers. It has 12 adjustable temperature points (-20, -10, 0, +10, +30, +50, +100, +195, +250, +500, +800 and +1000°C). Battery Powered, 2 x AAA Alkaline batteries (life 300 Hours). Comes with a five point UKAS Certificate of Calibration which indicates deviations from standards at the various points and a one meter PVC type J thermocouple lead with miniature connector.

£140.00
or call us for a quote
271-202

The MicroCal 2 T-Type Thermocouple Simulator helps to ensure the frequent checking of thermometer accuracies is a routine operation. Designed to simulate a chosen temperature to test T-Type Thermocouple thermometers. It has 12 adjustable temperature points (-20, -10, 0, +10, +30, +50, +100, +195, +250, +500, +800 and +1000°C). Battery Powered, 2 x AAA Alkaline batteries (life 300 Hours). Comes with a five point UKAS Certificate of Calibration which indicates deviations from standards at the various points and a one meter PVC type T thermocouple lead with miniature connector.

£140.00
or call us for a quote
 
MicroCal 3 Simulators
271-210

The MicroCal 3 K-Type Thermocouple Simulator helps to ensure the frequent checking of thermometer accuracies is a routine operation. Designed to simulate a chosen temperature to test K-Type Thermocouple thermometers. It has 23 Fixed temperature points (-100, -50, -20, -10, 0, +10, +20, +30, +40, +50, +60, +80, +100, +150, +195, +250, +300, +400, +500, +600, +800, +1000 and +1200°C.). Battery Powered, 2 x AAA Alkaline batteries (life 300 Hours). Comes with a five point UKAS Certificate of Calibration which indicates deviations from standards at the various points and a one meter PVC type K thermocouple lead with miniature connector.

£135.00
or call us for a quote
271-211

The MicroCal 3 J-Type Thermocouple Simulator helps to ensure the frequent checking of thermometer accuracies is a routine operation. Designed to simulate a chosen temperature to test J-Type Thermocouple thermometers. It has 23 fixed temperature points (-100, -50, -20, -10, 0, +10, +20, +30, +40, +50, +60, +80, +100, +150, +195, +250, +300, +400, +500, +600, +800, +1000 and +1200°C.). Battery Powered, 2 x AAA Alkaline batteries (life 300 Hours). Comes with a five point UKAS Certificate of Calibration which indicates deviations from standards at the various points and a one meter PVC type J thermocouple lead with miniature connector.

£135.00
or call us for a quote
271-212

The MicroCal 3 T-Type Thermocouple Simulator helps to ensure the frequent checking of thermometer accuracies is a routine operation. Designed to simulate a chosen temperature to test T-Type Thermocouple thermometers. It has 23 fixed temperature points (-100, -50, -20, -10, 0, +10, +20, +30, +40, +50, +60, +80, +100, +150, +195, +250, +300, +400, +500, +600, +800, +1000 and +1200°C.). Battery Powered, 2 x AAA Alkaline batteries (life 300 Hours). Comes with a five point UKAS Certificate of Calibration which indicates deviations from standards at the various points and a one meter PVC type T thermocouple lead with miniature connector.

£135.00
or call us for a quote
 
UKAS Recalibration
890-235
5 point UKAS Certificate providing proof that your temperature simulator has been calibrated against nationally approved standards. Simulator calibrated at -20°C, 0°C, 100°C, 199°C and 500°C. Each certificate indicates the deviation from standard at each calibration point.
View FileRecalibration Return Form
   Size: (436.82 KB)
£93.00
or call us for a quote
 
Accessories
830-205
830-205
Protective PVC boot, suitable for all MicroCal simulators.
£8.50
or call us for a quote
816-100
816-100
Thermocouple lead set. This set comprises of six leads, one for each thermocouple type K, J, T, R/S, N and E.