Safeye Xenon 700 Open Path Gas Detection System

Safeye Xenon 700 Open Path Gas Detection System

Quick Overview

The Safeye Xenon 700 is an infrared transmitter used to detector hydrocarbons in wide areas in a variety of industrial applications, eg offshore platforms or oil & gas refineries. The Safeye systems consists of an infrared source and an infrared detector unit separated over a line of sight to detect and quantify flammable gas presence. The unit provides a 4-20mA output for any gas detection, alarm relays and an RS485 Modbus interface to a PC or the intrinsically safe handheld communicator kit. The detector and source units are ATEX approved, SIL2 certified. Both units and the tilt mounts are enclosed in 316L Stainless Steel and have an IP66/7 rating. These units are most often used in addition to point type gas detectors to monitor a wider area.
View Options

Details

Features

  • Hydrocarbons and Ethylene detection
  • Heated optics
  • Detection range up to 140m
  • 4-20mA and Modbus RTU outputs
  • 10 year warranty for the Xenon flash lamp
  • SIL2 according to IEC 61508

The Safeye Xenon 700 consists of an advanced Xenon Flash infrared transmitter (source) and infrared detector (receiver), separated over a line of sight from 13 feet (4 meters) up to 460 feet (140 meters) to detect and quantify flammable gas presence, even when challenged by extremely harsh environments where dust, fog, rain, snow or vibration can cause a high reduction of signal.

The open path analyzes atmospheric absorption at three selected spectral bands, two in a region where the target gas absorbs and one where it does not absorb. The ratio between these absorption lines can provide accurate information of the gas concentration along an optical path. When no gas is present, the two signals are equal whereas if gas is present, measurement and reference signals are different. These three singles contribute to the reduction of false diagnostics and assure high immunity to false alarms.

The Safeye monitors the level of gas present between the source and detector units and provides a measurement out in LEL.meters instead of in %LEL as used with point type gas detectors. Both examples below show gas clouds with a reading of 1 LEL.meter.

 

The Safeye Xenon 700 includes heated optics on the transmitter and receiver to address icing, condensation and snow and the infrared technology will maintain operational integrity up to 90% obstruction and accepts up to a 1°misalignment tolerance. No matter the application, the Safeye Xenon 700 is an ideal open path system and thousands of first generation units have been installed on offshore platforms, refineries and other onshore locations around the world.

Availability: Stock Item

 

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
Safeye Xenon 700 Open Path Gas Detection System
B104067
B104067
Safeye Xenon 700 Open Path Gas Detection System for Hydrocarbon detection, Type 701. Max line of sight distance 4 to 20m. Power Supply 18-32vDC. Electrical connection 2 x M25, 4-20mA output, Relay & RS485 Modbus Interface. System is supplied with one source and one detector, each with a tilt mount. ATEX & SIL2 certification.
View FileDatasheet (2.7MB)
   Size: (2.67 MB)
£6,208.09
or call us for a quote
B104231
B104231
Safeye Xenon 700 Open Path Gas Detection System for Hydrocarbon detection, Type 702. Max line of sight distance 15 to 70m. Power Supply 18-32vDC. Electrical connection 2 x M25, 4-20mA output, Relay & RS485 Modbus Interface. System is supplied with one source and one detector, each with a tilt mount. ATEX & SIL2 certification.
£6,208.09
or call us for a quote
B104068
B104068
Safeye Xenon 700 Open Path Gas Detection System for Hydrocarbon detection, Type 703. Max line of sight distance 50 to 140m. Power Supply 18-32vDC. Electrical connection 2 x M25, 4-20mA output, Relay & RS485 Modbus Interface. System is supplied with one source and one detector, each with a tilt mount. ATEX & SIL2 certification.
£6,391.41
or call us for a quote
B104211
B104211
Safeye Xenon 700 Open Path Gas Detection System for Hydrocarbon detection, Type 701. Max line of sight distance 4 to 20m. Power Supply 18-32vDC. Electrical connection 2 x 3/4 inch NPT, 4-20mA output, Relay & RS485 Modbus Interface. System is supplied with one source and one detector, each with a tilt mount. ATEX & SIL2 certification.
£6,208.09
or call us for a quote
B104238
B104238
Safeye Xenon 700 Open Path Gas Detection System for Hydrocarbon detection, Type 702. Max line of sight distance 15 to 70m. Power Supply 18-32vDC. Electrical connection 2 x 3/4 inch NPT, 4-20mA output, Relay & RS485 Modbus Interface. System is supplied with one source and one detector, each with a tilt mount. ATEX & SIL2 certification.
£6,208.09
or call us for a quote
B104212
B104212
Safeye Xenon 700 Open Path Gas Detection System for Hydrocarbon detection, Type 703. Max line of sight distance 50 to 140m. Power Supply 18-32vDC. Electrical connection 2 x 3/4 inch NPT, 4-20mA output, Relay & RS485 Modbus Interface. System is supplied with one source and one detector, each with a tilt mount. ATEX & SIL2 certification.
£6,391.41
or call us for a quote
B103471
B103471
Safeye Xenon 700 Open Path Gas Detection System for Ethylene detection, Type 723. Max line of sight distance 50 to 140m. Power Supply 18-32vDC. Electrical connection 2 x 3/4 inch NPT, 4-20mA output, Relay & RS485 Modbus Interface. System is supplied with one source and one detector, each with a tilt mount. ATEX & SIL2 certification.
£6,391.41
or call us for a quote
 
Alignment Kit
B103479
Alignment kit for Safeye detectors. (includes telescope, test filter and case)
£227.00